CONFIGURING NETWORK (IP) SETTINGS
The fastest way to set basic network parameters is by using the front panel
keypad and display.
Note: If you prefer, you can get started by following a Quick Setup script on the
command line interface using Telnet or SSH, or by connecting a terminal directly to
the console (RS-232) port.The web page interface also provides a Quick Setup page.
See Quick Setup in the User Guide for instructions.
•
Use the right and left arrow buttons to navigate from one option to another.
•
Use the up and down arrow buttons to navigate between parameters within
an option or to increase or decrease a numerical value.
•
Use the Enter button in the center to enter or exit editing mode and to save changes.
Note: If no buttons are pressed for 30 seconds, the front panel display times out with-
out accepting unsaved changes and returns to displaying the hostname and clock.
For example, to change the IP settings:
1. Press the right arrow button to display the Network
Settings option and the current IP address.
2. Press the Enter button to go into editing mode.
3. Use the up and down arrow buttons to increment or
decrement the IP address indicated by the cursor.
4. Use the right and left arrow buttons to move to and change the remaining digits
of the IP address. Press the Enter button to exit editing mode when finished.
5. Press the down arrow button to display the Subnet Mask setting.
6. Edit the Subnet Mask in the same fashion as the IP address and press the down arrow.
7. Edit the Gateway and DNS settings.
8. Press the down arrow after the DNS 3 setting to go to the Save settings?
Yes/No prompt.
6
CONFIGURING NETWORK (IP) SETTINGS CONTINUED
9. Select Yes at the prompt and press Enter to save changes.
Repeat steps 1-8 for the other options (console port and date/time).
Note: Another option, release, is for restoring factory defaults. The default
password for this action is 999999.
After you save the values for your console manager, changes take effect immediately.
LOGGING IN TO THE SLC WEB PAGE
This section includes instructions for accessing both the web page and the
command line interfaces. You can use either method to configure all parameters.
To log in to the SLC web page:
1. Open a web browser (Netscape 8.1 Navigator and later or Internet 6.0 Explorer
and later).
7
Q u i c k S t a r t G u i d e
S L C C o n s o l e M a n a g e r s