Typical Wiring Diagrams
Fig 1.2
Page 11
Fig 1.2 shows a typical set-up of Ledion LU3’s, LU6’s or LU12’s all
fixtures should be connected to the LUD36 power supply with RJ45 data
cables into the LUT (tee piece), (see fig 1.3) the fixture is then plugged
into the port marked LED, the cable coming from the LUD36 is plugged
into the port marked IN the cable to the next fixture is plugged into
the port marked OUT. When you come to the last fixture an LUC/EL
should be used in place of the tee as you do not need to carry on to any
other fixtures, the LUC/EL can be used for the end of the line or as an
in line connector to extend data cables.
Fig 1.3
LUT
(tee piece)
The LUD36 will run 36 LED’s therefore you can run as follows;
12 x LU3’s (11xLUT, 1xLUC/EL)
6 x LU6’s (5xLUT, 1xLUC/EL)
3 x LU12’s (2xLUT, 1xLUC/EL
Warning. The Max Cable run on each LUD36 should not
exceed 20m.