Logic L60CHDB10 Instruction & Installation Manual - page 20
20
• Ventilation can be maintained by air inlets which
must not be blocked, in windows, doors and
outside wall vents, or by other technical measures,
such as ensuring that the cooker hood can only
be switched on when the heating appliance is
switched off or vice versa.
A ventilation brick alone is not generally sufficient
to ensure safe ventilation.
• One of the following technical measures may be
necessary to ensure safe operation.
• If the only way of ensuring adequate ventilation
is via an open window, a window contact switch
should be fitted to ensure that the cooker hood
can only operate when the window is opened
sufficiently. A window contact switch kit is
available from good builders' merchants. Take
care when ventilating the room through an open
window that ventilation is not impaired by a closed
blind or curtain.
If the hood is being operated in recirculation mode,
the above restrictions do not apply.
Correct Installation
• Refer to the cooker or hob manufacturer's
instructions as to whether a cooker hood may be
operated above the cooker/hob.
• The minimum safe distances between the top of
the cooker or hob and the bottom of the cooker
hood given in the Installation section of this
booklet must be maintained, unless the hob/
cooker manufacturer states that a greater safe
distance is required.
• If more than one appliance is fitted beneath the
cooker hood, and they have different minimum
safe distances to the cooker hood, select the
greater distance.
• Safety regulations prohibit the fitting of a cooker
hood over solid fuel stoves.
• All ducting, pipework and fittings must be of non-
flammable material. These can be obtained from
builders' merchants.
• The appliance must not be connected to a chimney
or vent flue which is in use. Neither should it be
connected to ducting which ventilates rooms with
fireplaces.
• If exhaust air is to be extracted into a chimney or
ventilation duct no longer used for other purposes,
seek professional advice.
Accessories
• Only use genuine original spare parts and
accessories with this appliance.
The overall ventilation condition of the
dwelling must be taken into account. If
in any doubt, the advice of a competent
builder or, for gas, a qualified gas fitter
(Gas Safe registered in the UK) must be
sought.
If in any doubt , the advice of a qualified
builder, gas fitter (Gas Safe registered in
the UK) or electrician must be sought.
The manufacturer cannot be held liable
for damage caused by non-compliance
with these Warning and Safety
instructions.