Madell Technology Corporation TYR108C Manual - Madell Technology, Corp.
Madell Technology, Corporate Office, 1141 E Philadelphia Street, Ontario, CA 91761
t. 877-670-9023 f. 909-418-6956
Website:
www.madelltech.com
; Technical Service Email: info@madelltech.com
20
Madell Technology, Corp.
there is electrical continuity between two contacts at high voltage side. If yes, replace the relay. If
not, please contact the technicians in Madell Technology.
E. After the power switch is tuned on, there is no display or the fan does not run:
Check whether the power supply is turned on. If the power supply is normal but the failure
still exists, open the baffle plate at right side to check whether the fuse on the control board is
open. If yes, use one of the three 30A fuses supplied with the machine to replace the failed fuse.
After replacement, start the machine again. If the above failure still exists, you should ask
professionals for check.
F. Abnormal sound from fan:
Turn off power first, and then flip the upper housing to check whether the vanes of fan touch
the machine body. If yes, please loosen the fastening screws for the vanes of fan, adjust suitably
the back-and-forth position of the vanes of fan and then tighten the fastening screws for the
vanes of fan.
G. Strong foreign flavor during operation
Check whether the temperature is set too high, which causes the carbonization of PCB or
foreign matters such as paper scrap, foreign bodies, oil stain etc. If the above matters are
removed but the foreign flavor still exists, turn off the power immediately and ask professionals for
check.
H. There is no reserved external ventilating interface on this equipment, so the equipment
shall be installed at a ventilating and dry place to ensure fresh indoor air.
I. After 18 months of continuous running of the cooling fan for electric cabinet, and the
cooling fan for recirculating blower etc., please pay attention to whether the fans are operate
normally; if abnormality occurs, replace the failed fans to ensure normal running of the
equipment.
This brochure is prepared by Madell Technology Corp. Madell Technology Corp. has the right
to change or improve the brochure for possible typing error, noncompliance with the latest
information, and program or equipment improvement. These changes will not be notified of
further, but will be incorporated in the latest revision of the brochure. Madell Technology Corp.
has the final right to interpret this brochure.
7. Contact Us
Madell Technology, Corporate Office
Address: 1141 E. Philadelphia Street, Ontario, California 91761, US
Phone: 877-670-9023
Fax: 909-418-6956
For our other locations please refer to our website: