3. Instructions for Installation and Operation
After unpacking the product, check if it is damaged from transportation and then check the part
list. If the packed contents are not compliant with the part list, contact our company or your local
branch or dealer. If there is no local branch or dealer at your location, please contact directly our head
office in Beijing. Prior to installation and operation, please read the brochure carefully.
3.1 Unpack to Check and Accept Equipment
1. Open packaging box
Check the packaged contents for all parts listed on the packing list and then inspect if there is
appearance damage of the machine. If there are issues found from the above check, do not install the
machine, and contact our company as soon as possible.
2. Check the model number of the reflow soldering machine
Beijing Madell Technology Corp. TYR108C
3.2 Points for Attention for Installation
3.2.1 Location
Do not install the machine at a location with powder, corrosive gas, moisture, rain attack, high
temperature, electromagnetism, high-frequency pulse interference, vibration, and/or shock etc. Do not
store flammable, explosive and/or volatile chemicals around the reflow soldering machine, and be
sure to keep certain room for operation and maintenance.
3.2.2 Environmental Conditions
Ambient temperature: -10 - +48°C
Ambient humidity: not more than 85%RH
Storage temperature: -10 - +60°C
Storage humidity: not more than 85%RH
Altitude above sea level: not higher than 2200m
The ambient environment around the reflow soldering machine shall not change sharply.
3.2.3 How to Install the Machine
For the installation of this reflow soldering machine, a single phase air switch with earth leakage
protection, of which the contact capacity is not less than 16A, needs to be installed between the
machine and the fixed power supply.
The power supply used for the reflow soldering machine is single phase three wire AC220V (with
PE protection), and the rated power of the machine is not less than 4kW.
The protective earth (PE) can be used as electrostatic grounding wire the same time, but the
grounding resistance must meet relevant requirements.
The power plug of the reflow soldering machine shall be attached to a socket with a rated current
not less than 16A.
The reflow soldering machine shall be put on a stable work stand, and if a steel stand is used, be
sure to provide electrostatic grounding wire.
3.3 Instructions for Operation
3.3.1 Prior to Starting the Machine
Carry out necessary check, because the vibration during long-distance transport may cause
loosening of fixed wire in the machine. Check if the live conductor and the earth conductor in the
power plug are shorted and if the metal part of the machine casing is shorted to that of the power plug.
If the above problem occurs, contact us immediately. Confirm that the power supply used is compliant