Majestic 360DVS2 Installation instructions & homeowner's manual

Manual is about: Multisided Top/Rear Vent Convertible Direct Vent Fireplaces

Summary of 360DVS2

  • Page 1

    Installation instructions & homeowner's manual 10002547 09/03 rev.8 installer: do not discard this manual—leave for homeowner multisided top/rear vent convertible direct vent fireplaces: 360dvs2 360dvs3 360dvsl 360dvsr please read this manual before installing and using appliance. Important: read al...

  • Page 2

    2 vermont castings, majestic products, 360dvs series 10002547 appliance installation instructions notes for safe installation and operation ............................................................................. 3 proposition 65 warning ............................................................

  • Page 3

    3 vermont castings, majestic products, 360dvs series 10002547 this gas appliance should be installed by a qualified installer in accordance with local building codes and current csa-b149.1 installation codes for gas burning appliances and equipment. If the unit is being installed in a mobile home, t...

  • Page 4

    4 vermont castings, majestic products, 360dvs series 10002547 ref. Rear vent configuration top vent configuration a 38 1 / 8 ” (968 mm) 38 1 / 8 ” (968 mm) b 43 1 / 4 ” (1099 mm) 43 1 / 4 ” (1099 mm) c 24” (610 mm) 24” (610 mm) d 24” (610 mm) 24” (610 mm) e 37 3 / 8 ” (949 mm) 37 3 / 8 ” (949 mm) f ...

  • Page 5

    5 vermont castings, majestic products, 360dvs series 10002547 top vent configuration rear vent configuration ref. Rear vent configuration top vent configuration a 38 1 / 8 ” (968 mm) 38 1 / 8 ” (968 mm) b 40 5 / 8 ” (1032 mm) 40 5 / 8 ” (1032 mm) c 24” (610 mm) 24” (610 mm) d 24” (610 mm) 24” (610 m...

  • Page 6

    6 vermont castings, majestic products, 360dvs series 10002547 roh rod row rear vent configuration rod roh row top vent configuration framing dimensions - 360dvs2 framing dimensions ref. Rear vent configuration top vent configuration rod 24” minus two times finishing material thickness to be even wit...

  • Page 7

    7 vermont castings, majestic products, 360dvs series 10002547 framing dimensions - 360dvs3/ 360dvsl/ 360dvsr rear vent configuration top vent configuration framing dimensions ref. Rear vent configuration top vent configuration model 360dvs3 360dvsl/r 360dvs3 360dvsl/r rod (see note 1) (see note 2) (...

  • Page 8

    8 vermont castings, majestic products, 360dvs series 10002547 appliance top 0” (0 mm) to standoff bottom 0” (0 mm) vent end 1 / 2 ” (13 mm) to rear panel nonvent end (dvs2) 0” (0 mm) venting concentric sections of dv vent: top, bottom & sides 1” (25 mm) nonconcentric sections of dv vent: side and bo...

  • Page 9

    9 vermont castings, majestic products, 360dvs series 10002547 1234567890123456789012345678901 1234567890123456789012345678901 1234567890123456789012345678901 1234567890123456789012345678901 1234567890123456789012345678901 1234567890123456789012345678901 360dvs2/ 360dvs3/ 360dvsl/ 360dvsr certified t...

  • Page 10

    10 vermont castings, majestic products, 360dvs series 10002547 alternative switch location the remote switch can be installed on the front or the side of the access door. Simply mount the switch to the bracket provided and screw the bracket to either side of the frame, lining up the screws with the ...

  • Page 11

    11 vermont castings, majestic products, 360dvs series 10002547 optional top vent application fig. 7 remove these screw outer collar adapter remove these screws fig. 8 alternate switch location on/off_switch_loc fig. 9 remove screws from outer collar adapter this appliance is shipped as a rear vent u...

  • Page 12

    12 vermont castings, majestic products, 360dvs series 10002547 your fireplace is approved to be vented either through the side wall, or vertically through the roof. • only vermont castings, majestic products venting components, specifically approved and labeled for this fireplace, may be used. • ven...

  • Page 13

    13 vermont castings, majestic products, 360dvs series 10002547 canadian installations 1 us installations 2 a = clearance above grade, veranda, porch, 12 in. (30 cm) 12 in. (30 cm) deck or balcony b = clearance to window/door that may be opened 6 in. (15 cm) for appliances (3 kw), 12 in (30 cm) for a...

  • Page 14

    14 vermont castings, majestic products, 360dvs series 10002547 outside corner inside corner termination clearances termination clearances for buildings with combustible and noncombustible exteriors. A = combustible 6" (152 mm) noncombustible 2" (51 mm) b = combustible 6" (152 mm) noncombustible 2" (...

  • Page 15

    15 vermont castings, majestic products, 360dvs series 10002547 crimped end pipes before joining elbows and pipes apply a bead of high- temperature sealant to the crimped end of the elbow or pipe. Join the pipes using a 2” (51 mm) overlap and secure the joints with three sheet metal screws (fig. 15)....

  • Page 16

    16 vermont castings, majestic products, 360dvs series 10002547 #8 screws (2) #8 screws (2) maximum length 12 in. (304.8 mm) firestop (side view) cfm135a for combustible walls: cut a rectangular hole measuring 10 3 / 8 in.H x 9 3 / 8 in.W (265 mm x 240 mm) through the exterior wall and frame. Frame i...

  • Page 17

    17 vermont castings, majestic products, 360dvs series 10002547 • if a 90 ° elbow is used in the horizontal vent run (level height maintained), the maximum horizontal vent length is reduced by 36 in. (914 mm) (fig. 23). This does not apply if the 90 ° elbows are used to increase or redirect a vertica...

  • Page 18

    18 vermont castings, majestic products, 360dvs series 10002547 horizontal distance x x x fig. 28 horizontal length requirements step 1 locate and cut vent opening in the side wall. It may be necessary to first position the fireplace and measure to obtain the hole location. Depending on whether the w...

  • Page 19

    19 vermont castings, majestic products, 360dvs series 10002547 when it is not possible to meet required vent terminal clearances of 12 in. (305 mm) above grade level, we recommend using a starter kit. It allows installation depth down to 7 in. (178 mm) below grade level. Measure 7 in. (178 mm) from ...

  • Page 20

    20 vermont castings, majestic products, 360dvs series 10002547 this gas fireplace has been approved for: • vertical installations up to 40 ft. (12 m) in height. Up to a 10 ft. (3 m) horizontal vent run can be installed within the vent system using a maximum of two 90 ° elbows (fig. 31). • the minimu...

  • Page 21

    21 vermont castings, majestic products, 360dvs series 10002547 if there is a room above ceiling level, a firestop spacer must be installed on both the bottom and the top sides of the ceiling joists (fig. 36). If an attic is above ceiling level, a 7dvais (attic insulation shield) must be installed. N...

  • Page 22

    22 vermont castings, majestic products, 360dvs series 10002547 7 dvrvt through-the-wall rear vent termination starter kit model 7tdvsk—sidewall/ rearwall venting starter kit model 7tdvskv—vertical venting • for 7tdvskv-a: order 1/12 to 6/12 roof pitch • for 7tdvskv-b: order 7/12 to 12/12 roof pitch ...

  • Page 23

    23 vermont castings, majestic products, 360dvs series 10002547 7 dvrvt through-the-wall rear vent termination starter kit model 7dvsk—sidewall/rearwall venting starter kit model 7tdvskv—vertical venting • for 7dvskv-a: order 1/12 to 6/12 roof pitch • for 7dvskv-b: order 7/12 to 12/12 roof pitch • fo...

  • Page 24: Operating Instructions

    24 vermont castings, majestic products, 360dvs series 10002547 only glass approved by vermont castings, majestic products should be used on this fireplace. • the use of any nonapproved replacement glass will void all product warranties. • care must be taken to avoid breakage of the glass. • under no...

  • Page 25

    25 vermont castings, majestic products, 360dvs series 10002547 b39 b39 b40 b40 b42 b42 b41 b41 side of the fireplace it is necessary to periodically clean glass. During startup, condensation, which is normal, forms on the inside of the glass. This condensation causes lint, dust and other airborne pa...

  • Page 26

    26 vermont castings, majestic products, 360dvs series 10002547 rn/ rp models for units equipped with ‘hi/ lo’ valves the flame adjustment is accomplished by rotating the ‘hi/ lo’ adjustment knob located near the center of the gas control valve (fig. 43 and fig. 44). It is important to periodically p...

  • Page 27

    27 vermont castings, majestic products, 360dvs series 10002547 1. Stop! Read the safety information above. 2. Turn off all electrical power to the fireplace. 3. For mn/mp/tn/tp appliances only, go on to step 4. For rn/rp appliances turn the on/off switch to “off” position or set thermostat to lowest...

  • Page 28

    28 vermont castings, majestic products, 360dvs series 10002547 lighting and operating instructions for fireplaces equipped with sit822 gas valve (en or ep) a. This fireplace is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand. B. Before ope...

  • Page 29

    29 vermont castings, majestic products, 360dvs series 10002547 note: before troubleshooting the gas control system, be sure external gas shut off is in the “on” position. Sit nova 820 millivolt valve troubleshooting the gas control system warning: remove glass front before doing any gas control serv...

  • Page 30

    30 vermont castings, majestic products, 360dvs series 10002547 sit 822 valve with a honeywell electronic igniter note: remove glass before servicing. Start turn gas supply off. Turn on/off switch to call for heat. Power to module? (24v normal) spark across ignitor sensor gap? Yes yes yes turn gas on...

  • Page 31

    31 vermont castings, majestic products, 360dvs series 10002547 troubleshooting: honeywell vs8421 honeywell millivolt valve gas supply on. • supply line hooked up. • shutoff valve open. No no no no • lockout has engaged. Wait 60 seconds and try again. • for spark at electrode while depressing piezo (...

  • Page 32

    32 vermont castings, majestic products, 360dvs series 10002547 fig. 48 sit pressure regulator replacement 820 lp/ng air shutter retaining screws air shutters 1. Disconnect power to unit and shut off the gas supply. 2. Remove window frame assembly (see “window frame assembly removal” section). 3. Car...

  • Page 33

    33 vermont castings, majestic products, 360dvs series 10002547 honeywell fig. 49 honeywell conversion screw replacement 10. Reassemble fireplace in the reverse order, except for the window frame assembly. Leave this off until after unit has been checked for leaks and the gas supply has been bled. 11...

  • Page 34: 360Dvs Series

    34 vermont castings, majestic products, 360dvs series 10002547 lo h i pilo t adj pilo t on off 4a/b 5a/b 6 11 9 11 8 10 7 12 17 24 27 18 2 29 30 28 31 22 23 26 21 20 25 19 13 14 3a/b 15a/b 16a/b 32 1a (x2) 1b (x2) 1c (x2) 1d (x2) 33a/b 34 37 35 hi lo 36a/b 25 38 39 2547/ 503 vermont castings, majest...

  • Page 35: 360Dvs Series

    35 vermont castings, majestic products, 360dvs series 10002547 360dvs series (items marked ‘*’ are not shown in the parts illustration) ref. Description 360dvs2 360dvs3 360dvsl 360dvsr 1. Log set (complete) 10002523 10002523 10002523 10002523 1a. Log - left rear & right front b39 b39 b39 b39 1b. Log...

  • Page 36: 360Dvs Series

    36 vermont castings, majestic products, 360dvs series 10002547 360dvs series (continued) (items marked ‘*’ are not shown in the parts illustration) ref. Description 360dvs2 360dvs3 360dvsl 360dvsr 19. Remote on/off switch (rn/rp models) 51842 51842 51842 51842 * wiring harness (remote switch) 55923 ...

  • Page 37

    37 vermont castings, majestic products, 360dvs series 10002547 optional accessories available fan kits maintenance the fan itself does not require regular maintenance; however, periodic cleaning of the fan and the surrounding area is required. Check the area under the control door (lower louvre asse...

  • Page 38

    38 vermont castings, majestic products, 360dvs series 10002547 trim - bottom trim - top trim window top/bottom s c r e w s s c r e w s screws screws top trim piece top deflector plate trim-left trim-right method b for instruction on wiring the eb-1 electrical junction box, see section eb-1 electrica...

  • Page 39

    39 vermont castings, majestic products, 360dvs series 10002547 • if upon inspection, the damage is found to be the fault of the manufacturer, repairs will be authorized at no charge to the customer parts and/or labor. • any part and/or component replaced under the provisions of this warranty is cove...