Majestic 360DVS2 Installation instructions & homeowner's manual - page 9
9
Vermont Castings, Majestic Products, 360DVS Series
10002547
1234567890123456789012345678901
1234567890123456789012345678901
1234567890123456789012345678901
1234567890123456789012345678901
1234567890123456789012345678901
1234567890123456789012345678901
360DVS2/ 360DVS3/ 360DVSL/ 360DVSR
CERTIFIED TO
ANSI Z21.88b-1999/ CSA 2.33b-M99
Vented Gas Fireplace Heaters
Final Finishing
Input ratings are shown in BTU per hour and are
certified without deration for elevations up to
4,500 feet (1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the
current ANSI Z223.1 and/or local codes having
jurisdiction.
In Canada, please consult provincial and/or local
authorities having jurisdiction for installations
above 4,500 feet (1,370 m).
When purging the gas lines, the window
frame assembly must be removed.
The gas pipeline can be brought in through the vent
end of the fireplace as well as the bottom. Knockouts
(to allow gas pipe installation and testing any gas
connection) are provided on the bottom behind the
valve. It is most convenient to bring the gas line in from
the vent end of the valve, as this allows fan installation
or removal without disconnecting the gas line.
The gas line connection can be made with properly
tinned
3
/
8
” copper tubing,
3
/
8
” rigid pipe, or an approved
flex connector. Since some municipalities have
additional local codes, it is always best to consult your
local authority and the CSA-B149.1 installation codes.
For USA installations, consult the current National Fuel
Gas Code, ANSI Z223.1.
Always check for gas leaks with a mild
soap and water solution. Do not use an
open flame for leak testing.
Gas Line Installation
Noncombustible materials such as brick or tile may be
extended over the edges of the face of the appliance.
DO NOT cover any vent or grille panels.
If a Trim Kit is going to be installed on the fireplace, the
brick or tile will have to be installed flush with the
edges of the appliance.
1. Choose the unit location.
2. Place the unit into position and secure it to the floor
with 1.5” (38 mm) screws or nails. Holes to secure
the unit to the floor are located behind the access
door grille on the left and right sides of the unit.
3. Frame in the fireplace with a header across the top.
It is important to allow for the finished wall face
when setting the depth of the frame.
4. Drywall (sheetrock) or wood material may be placed
with a zero clearance to the top edges of the
appliance when finishing walls above sides of the
appliance with glass windows. NOTE: Attach wall
finishing to constructed frame, not the appliance.
5. On 360DVSL and 360DVSR, drywall, wood, or
wood molding may be placed with zero clearance
to the rear wall of the unit, along the vertical edge
formed by the standoffs, to intersection of the rear
wall, to the side wall having the small glass window.
NOTE: Attach wall finishing to constructed
frame, not the appliance.
Framing & Finishing
FP297a
1/2” GAS SUPPLY
1/2” NPT x 1/2” FLARE
SHUT-OFF VALVE
3/8” FLEX LINE
(FROM VALVE)
Fig. 5 Gas shutoff valve and flex connector
Gas Inlet & Manifold Pressures
Natural
LP (Propane)
Inlet Minimum
4.5” wc
11” wc
Inlet Maximum
14” wc
14” wc
Manifold Pressure
3.5” wc
10” wc
1234567890123456789012345678901212345678901234567
1234567890123456789012345678901212345678901234567
1234567890123456789012345678901212345678901234567
1234567890123456789012345678901212345678901234567
1234567890123456789012345678901212345678901234567
1234567890123456789012345678901212345678901234567
Max.
Max.
Input
Input
Model
Fuel
Gas Control
BTU/h
BTU/h
360DVS2RN
Nat
Millivolt
38,000
26,600
360DVS2RP
Prop
Millivolt
38,000
28,500
360DVS2EN
Nat
24V Hi/Lo
38,000
26,600
360DVS2EP
Prop
24V Hi/Lo
38,000
28,500
360DVS3RN
Nat
Millivolt
38,000
26,600
360DVS3RP
Prop
Millivolt
38,000
28,500
360DVS3EN
Nat
24V Hi/Lo
38,000
26,600
360DVS3EP
Prop
24V Hi/Lo
38,000
28,500
360DVSLRN
Nat
Millivolt
38,000
26,600
360DVSLRP
Prop
Millivolt
38,000
28,500
360DVSLEN
Nat
24V Hi/Lo
38,000
26,600
360DVSLEP
Prop
24V Hi/Lo
38,000
28,500
360DVSRRN
Nat
Millivolt
38,000
26,600
360DVSRRP
Prop
Millivolt
38,000
28,500
360DVSREN
Nat
24V Hi/Lo
38,000
26,600
360DVSREP
Prop
24V Hi/Lo
38,000
28,500
Gas Specifications