Meen Green MGP-20 Owner's Manual - page 28
Reconnecting the Batteries (Lithium Modules)
1. Reverse process of disconnecting the battery (Fig.H).
2. Plug RED battery quick disconnect handle into right side of battery connecting port.
Battery Storage
To maximize battery life it is best to fully charge batteries
shortly after each use.
The Mean Green Mower charger is designed to remain plugged into the vehicle and turned
ON during storage. If the charger remains on and connected it will automatically maintain
the charge level of the battery pack. All batteries self discharge over time.
If the mower can not remain plugged in and on charger then it is required that
the battery pack be charged for a minimum of 12 hours every 30 days.
Failure to maintain the battery charge level will void the battery warranty.
TROUBLESHOOTING
SYMPTOMS & PROBABLE CAUSES
SUGGESTED REMEDIES
FOR ANY ELECTRICAL PROBLEMS
****RESET Mower Electronics by Switching Ignition Key to OFF position for approximately 5
seconds & then back to ON position.******
Battery Will Not Charge
MAKE SURE THAT THE
Ignition Key Switch is turned
to FULL CLOCKWISE “ON” position
for battery to accept charge.
Mower blades stop while mowing
When battery voltage becomes low, the mower blades will stop. When the batteries
discharge to this point they require recharging. The unit should immediately be
returned to the battery charging area and the unit connected to the battery
charger.
Uneven cutting height
The blade(s) are not sharp. Sharpen the blades.
A cutting blade(s) is/are bent. Install new cutting blade(s).
The deck is not level - Contact your Mean Green Products Dealer.
The underside of the deck is dirty. Clean the underside of the deck.
A blade spindle is bent. Contact your Mean Green Products Dealer.
Fig. H