MEGATRONIX Viking VS 2000 Installation Manual - page 4
#H5 6 PIN WHITE CONNECTOR FOR OUTPUT CONNECTION
1. White Wire: (-) 200 mA Programmable output
Dome Light Control Output (Factory Default setting)
Or Horn Output
Or Factory Security Rearm Signal Output
Or Ground Output During Start (Crank).
6. Orange Wire: (-) 500mA Grounded Output When Armed
4. Gray Wire: (-) 200 mA Channel 3 (Trunk) Output
2. Yellow Wire: (-) 200 mA Ignition 3 Control Output
5. Pink Wire: (-) 200 mA Programmable output
2-Step Door Unlock Output (Factory Default setting)
Or Factory Security Disarm Signal Output
Or Start Status (Shock Sensor Bypass Control) Output
3. Black / Green Wire: (-) 200 mA Time Control Channel 4 Output
#H7. 8 PIN BLACK CONNECTOR FOR INPUT CONNECTION:
2. Green Wire: Zone 3 Negative Door Pin Trigger Input:
1. Blue Wire: Zone 2 Instant Trigger Ground Input
3. Violet Wire: Zone 3 Positive Door Pin Trigger
7. White/Violet Wire: (
+
) Positive Safety Shut Down Input for Brake switch.
6. Black/White Wire: (
-
) Neutral Safety Switch Input &
(
-
) Remote Start Toggle Switch Input
8. White/Red Wire: Tach. Signal Input
+12V
5. White/Black Wire: (
-
) Negative Safety Shut Down Input for Hood pin switch
IMPORTANT NOTE: Directly connect the H7/6 BLACK/WHITE wire to the “GROUND” when this wire
is not used.
+12V
4. White/Blue Wire: (-) Instant Start and Turn Off Input.
4