NAPCO Gemini GEM-P3200 Programming Instructions Manual

Manual is about: CONTROL PANEL/COMMUNICATOR

Summary of Gemini GEM-P3200

  • Page 1

    Hardwire wireless g e m - p 3 2 0 0 control panel/communicator programming the gem-p3200 control panel with the "classic" gem-rp2ase2, gem-rp3dgtl, and gem-rp4rfc/gem-rp4c keypads and the "k series" gem-k2as, gem-k3dgtl, and gem-k4rf/gem-k4 keypads wi1184b 2/06 © napco 2006 r publicly traded on nasd...

  • Page 2

    This manual includes features which are only available in control panel firmware version 50 or later. Important note this manual supports the keypad programming of the gem-p3200 control panel with the napco "classic" gem- rp2ase2, gem-rp3dgtl and gem-rp4rfc/gem-rp4c keypads as well as the gem-k2as, ...

  • Page 3

    L napco security systems x gem-p3200 programming instructions page 3 wi1184b 2/06 table of contents refer to accompanying gem-p3200 installation instructions (wi817) for installation information. Important note ......................................................................................2 c...

  • Page 4

    X gem-p3200 programming instructions l napco security systems page 4 wi1184b 2/06 system programming options introduction the gem-p3200 control panel may be programmed by various means, each of which will be covered in detail in the sections that follow. Keypad displays shown are for a gem-k2as, the...

  • Page 5

    L napco security systems x gem-p3200 programming instructions page 5 wi1184b 2/06 easy menu driven program mode dealer program - preliminary information only keypad #1 may be used for both dealer and user programming, however this keypad may be located in any area. The master security code is printe...

  • Page 6

    X gem-p3200 programming instructions l napco security systems page 6 wi1184b 2/06 gem-rp2ase2/gem-k2as keypad easy program menu enter the dealer security code (default = 456789) for a new panel or enter your custom dealer program code if programmed. Press the prior/no button repeatedly until “turnon...

  • Page 7

    L napco security systems x gem-p3200 programming instructions page 7 wi1184b 2/06 24 hour zones in area 1 (new program only) • enter the zone numbers of zones to be used as 24 hour zones. • valid entries are from 01 to 48. Directly enter each zone number, including leading zeros. • press u to save a...

  • Page 8

    X gem-p3200 programming instructions l napco security systems page 8 wi1184b 2/06 enable no eolr zones (new program only) • press yes to program all zones except 24 hr & fire zones for no end of line resistor. Press no to continue. • do not program this feature for ul installations. Enable telco lin...

  • Page 9

    L napco security systems x gem-p3200 programming instructions page 9 wi1184b 2/06 central station receiver 1 account number • enter an account number of up to four digits. • press 0 through 9 for digits 0–9, and g 0 for a blank ( • ). • press u to save and press the next/yes button to proceed. Note:...

  • Page 10

    X gem-p3200 programming instructions l napco security systems page 10 wi1184b 2/06 enter user codes (press the r button to set cursor.) enter up to 48 user codes with user options, authority level and access control options (if necessary) for each code. Refer to the tables below and on the next page...

  • Page 11

    L napco security systems x gem-p3200 programming instructions page 11 wi1184b 2/06 example: program a code of “2222” for user 02, with user option of “user program”, user “level 3” and access control option “keypad no. 1”. Enter “2222” for a user code, “2 3” for user option and “blank(•) 1” for acce...

  • Page 12

    X gem-p3200 programming instructions l napco security systems page 12 wi1184b 2/06 user options user code (up to 6 digits) user level acm area data entries access level code type blank (•) 0 none 1 1 none 2 2 none 4 0 arm/disarm 5 1 arm/disarm 6 2 arm/disarm 8 0 arm only 9 1 arm only 0 2 arm only no...

  • Page 13

    L napco security systems x gem-p3200 programming instructions page 13 wi1184b 2/06 gem -r p 2 a se2/ ge m- k2 a s keypa d e a sy prog ra m men u rf transmitter points (press r to set cursor.) for each transmitter enter: (for wireless systems only. Also see quick method, which follows) • the zone num...

  • Page 14

    X gem-p3200 programming instructions l napco security systems page 14 wi1184b 2/06 keyfob transmitters as zone input devices (refer to display above: press the prior button to go backwards). Each of the 4 keyfob buttons can be assigned to a zone. For example, on button = point 1; off button = point ...

  • Page 15

    L napco security systems x gem-p3200 programming instructions page 15 wi1184b 2/06 gem-rp3dgtl/gem-k3dgtl and gem-rp4rfc/gem-k4rf keypad easy program menu to enter dealer program mode, see page 5. Once entered, press r , followed by [prior/no] repeatedly until “17” is displayed (scroll back by press...

  • Page 16

    X gem-p3200 programming instructions l napco security systems page 16 wi1184b 2/06 interior zones in area 1 (new program only) • enter the zone numbers to be used as interior zones. • valid entries are from 01 to 48. Directly enter each zone number, including leading zeros. • press u to save and the...

  • Page 17

    L napco security systems x gem-p3200 programming instructions page 17 wi1184b 2/06 keypad sounder on alarm zones (new program only) • enter the zone numbers of all zones to activate the keypad sounder upon alarm. • valid entries are from 01 to 48. Directly enter each zone number, including leading z...

  • Page 18

    X gem-p3200 programming instructions l napco security systems page 18 wi1184b 2/06 central station receiver 1 telephone number • enter telephone number of up to 16 digits. • press 1 through 9 for digits 1–9; g 0 for a zero and 0 for a blank ( • ). • press g 1 through g 5 for letters b–f, respectivel...

  • Page 19

    L napco security systems x gem-p3200 programming instructions page 19 wi1184b 2/06 enter user codes (press the r button to set cursor.) enter up to 48 user codes with user options, authority level and access control options (if necessary) for each code. Refer to the tables below and on the next page...

  • Page 20

    X gem-p3200 programming instructions l napco security systems page 20 wi1184b 2/06 example: program a code of “2222” for user 02, with user option of “user program”, user “level 3” and access control option “keypad no. 1”. Enter “2222” for a user code, “2 3” for user option and “blank(•) 1” for acce...

  • Page 21

    L napco security systems x gem-p3200 programming instructions page 21 wi1184b 2/06 user options user code (up to 6 digits) user level acm area data entries access level code type blank (•) 0 none 1 1 none 2 2 none 4 0 arm/disarm 5 1 arm/disarm 6 2 arm/disarm 8 0 arm only 9 1 arm only 0 2 arm only no...

  • Page 22

    X gem-p3200 programming instructions l napco security systems page 22 wi1184b 2/06 rf transmitter points (press r to set cursor.) for each transmitter enter: (for wireless systems only. Also see quick method, which follows) • the zone number (01–48) to which the transmitter will be mapped. • the 6-d...

  • Page 23

    L napco security systems x gem-p3200 programming instructions page 23 wi1184b 2/06 keyfob transmitters as zone input devices (refer to display above: press the prior button to go backwards). Each of the 4 keyfob buttons can be assigned to a zone. For example, on button = point 1; off button = point ...

  • Page 24

    X gem-p3200 programming instructions l napco security systems page 24 wi1184b 2/06 this is an extension of the dealer program mode. This method of programming is used in conjunction with the keypad programming worksheets that follow. Refer to these worksheets to identify the address locations of the...

  • Page 25

    L napco security systems x gem-p3200 programming instructions page 25 wi1184b 2/06 keypad address program mode displays direct address program mode keypad commands a. Gem-k2as (and gem-rp2ase2) keypad to access, press c in dealer program mode 1. Toggle cursor to 4-digit ad- dress field using the r b...

  • Page 26: Gemini

    X gem-p3200 programming instructions l napco security systems page 26 wi1184b 2/06 b. Gem-k3dgtl/gem-rp3dgtl and gem-rp4rfc/gem-k4rf keypads note: “a” = g 0 ; “b” = g 1 ; “c” = g 2 ; “d” = g 3 ; “e” = g 4 ; “f” = g 5 . Press 0 for a zero or to clear. Example: gem-rp2ase2 / gem-rp3dgtl / gem-rp4rfc--...

  • Page 27

    L napco security systems x gem-p3200 programming instructions page 27 wi1184b 2/06 the displays shown on the previous pages will appear after a brief delay. Use r to toggle the cursor between the 4-digit address field and the data entry locations. Enter the address directly using the number buttons....

  • Page 28

    X gem-p3200 programming instructions l napco security systems page 28 wi1184b 2/06 system delays & timeouts (address 0000-0002, 2402, 2406, 2414 & 3902) left right address 0000 exit delay (sec.) [default = 3c] left right address 0001 entry delay 1 (sec.) [default = 1e] left right address 0002 entry ...

  • Page 29

    L napco security systems x gem-p3200 programming instructions page 29 wi1184b 2/06 system delays & timeouts (address 2400, 2401, 2403-2405, 4082 & 4083) left right blank (•) blank (•) blank (•) 1 blank (•) 2 blank (•) 3 blank (•) 4 blank (•) 5 blank (•) 6 1 blank (•) f f data entries delay/ timeout ...

  • Page 30

    X gem-p3200 programming instructions l napco security systems page 30 wi1184b 2/06 default for cs receiver 1 format depends on easy menu question “rcvr format”. [default = •(blank) (e)] for cs receivers 1, 2 and 3 formats. Cs receiver format options (address 0520, 0521, 0525, 0526, 0550, 0551, 0575 ...

  • Page 31

    L napco security systems x gem-p3200 programming instructions page 31 wi1184b 2/06 cs receiver 1 telephone number (digits 1-20) 0527 0528 0529 0530 0531 0532 0533 0534 0535 0536 0537 0538 0539 0540 0541 0542 0543 0544 0545 0546 r r r r r r r r r r r r r r r r r r r r address 0527-0546 (right digits ...

  • Page 32

    X gem-p3200 programming instructions l napco security systems page 32 wi1184b 2/06 cs subscriber id numbers (address 0650-0787) cs subscriber id nu mbers (telco 1 & 2) area 1 0650 0651 0652 0653 r r r r address 0650-0653 (right digits 1-4) cs telco 1 subscriber opening/closing id numbers area 2 0654...

  • Page 33

    L napco security systems x gem-p3200 programming instructions page 33 wi1184b 2/06 cs reporting codes (address 0859-0883) left addr right blank (•) 0859 blank (•) 0860 blank (•) 0861 blank (•) 0862 address 0860-0862 alarm/trouble reporting codes cancel alarm restore trouble trouble restore [default ...

  • Page 34

    X gem-p3200 programming instructions l napco security systems page 34 wi1184b 2/06 cs reporting codes: 1. Enter in corresponding address location (left and right digits). 2. Valid entries are: 1-9, 0 and b-f. Note: dark shaded data value box shows option not available. Left addr right 0870 0871 0872...

  • Page 35

    L napco security systems x gem-p3200 programming instructions page 35 wi1184b 2/06 address 0910-0917 zones report code (control panel) zone 1 zone 2 zone 3 zone 4 zone 5 zone 6 zone 7 zone 8 0910 0911 0912 0913 0914 0915 0916 l r l r l r l r l r l r l r l r 0917 address 0918-0921 zones report code (...

  • Page 36

    X gem-p3200 programming instructions l napco security systems page 36 wi1184b 2/06 cs user reporting codes (address 1030-1048) note: these opening events will report as the user number shown. Also, keyfobs 01-08 (see easy menu program driven mode) will report as users 25-32, respectively. User openi...

  • Page 37

    L napco security systems x gem-p3200 programming instructions page 37 wi1184b 2/06 cs user reporting codes (address 1056-1074) note: these opening events will report as the user number shown. Also, keyfobs 01-08 (see easy menu program driven mode) will report as users 25-32, respectively. User openi...

  • Page 38

    X gem-p3200 programming instructions l napco security systems page 38 wi1184b 2/06 glob a l syste m trouble reporting options global system trouble reporting options (address 1082-1116) [default = blank (•) blank (•) from address 1082-1092] system response activated by global event/trouble burglary ...

  • Page 39

    L napco security systems x gem-p3200 programming instructions page 39 wi1184b 2/06 a r e a system t r ouble reporting options area system trouble reporting options (address 1120-1137) 1. Select the desired option by circling the data values for each digit (left and right). 2. Add the data values (ex...

  • Page 40

    X gem-p3200 programming instructions l napco security systems page 40 wi1184b 2/06 zone options / zones 1-16 (address 1200-1386) zone options / zones 1-16 zone options zones 13-16 left data values (circle ) address 1302-1386 zones 9-12 right data values (circle ) zones 5-8 left data values (circle )...

  • Page 41

    L napco security systems x gem-p3200 programming instructions page 41 wi1184b 2/06 zone options / zones 17-32 (address 1402-1586) zone options / zones 17-32 see zone options on page 43. Zone options zones 29-32 left data values (circle ) address 1502-1586 zones 25-28 right data values (circle ) zone...

  • Page 42

    X gem-p3200 programming instructions l napco security systems page 42 wi1184b 2/06 zone opti ons / zones 33 -48 zone options / zones 33-48 (address 1602-1786) zone options zones 45-48 left data values (circle ) address 1702-1786 zones 41-44 right data values (circle ) zones 37-40 left data values (c...

  • Page 43

    L napco security systems x gem-p3200 programming instructions page 43 wi1184b 2/06 1. Select the desired zone option. ◄ zone options 50ms loop response 10ms loop response priority priority with bypass auto-bypass 2. Enable desired options for each zone by drawing a circle around its corresponding bi...

  • Page 44

    X gem-p3200 programming instructions l napco security systems page 44 wi1184b 2/06 [default = blank (•) (2)] [default = blank (•) blank (•)] [default = blank (•) blank (•)] system options (address 2415-2419) left digit (sum of data values) right digit (sum of data values) address 2415 system options...

  • Page 45

    L napco security systems x gem-p3200 programming instructions page 45 wi1184b 2/06 system options (address 2420-2422, 3874) [default = blank (•) blank (•)] *not for ul installations left digit (sum of data values) right digit (sum of data values) address 2420 system options disable keypad instant bu...

  • Page 46

    X gem-p3200 programming instructions l napco security systems page 46 wi1184b 2/06 [default = blank (•) blank (•) from address 3879-3881] left addr right blank (•) 3879 blank (•) 3880 blank (•) 3881 address 3879-3881 alarm/trouble reporting codes wireless low battery wireless supervisory wireless ta...

  • Page 47

    L napco security systems x gem-p3200 programming instructions page 47 wi1184b 2/06 right blank (•) 1 2 option not used area 1 area 2 keypad area assignment keypad options: select options for any of the 7 keypads. * note: for remote access control only (no arm/disarm capability). 1. Select the desire...

  • Page 48

    X gem-p3200 programming instructions l napco security systems page 48 wi1184b 2/06 ac m o p t io n s acm zone options (address 2740-2769) acm global flags (address 2780) acm timeouts (address 2782-2783) acm zone options: enter the zone numbers (in decimal 1-48 format) for each option in the table be...

  • Page 49

    L napco security systems x gem-p3200 programming instructions page 49 wi1184b 2/06 ac m o p t io n s acm door area options (address 2784-2787) acm scheduled free access (address 4072-4075) acm door number addr acm door area options arm all areas allowed disarm all areas allowed stealth mode rsrvd. R...

  • Page 50

    X gem-p3200 programming instructions l napco security systems page 50 wi1184b 2/06 ac m o p t io n s acm zone options: enter the zone numbers (in two-digit hexadecimal format) for each option in the table below. The left digit (nibble) determines the type of device: "●" for keypad and "1" for acm. T...

  • Page 51

    L napco security systems x gem-p3200 programming instructions page 51 wi1184b 2/06 system options (address 2423) system option: 1. Select the system option from the table shown and enter in the corresponding address location at right. Keypad blanking will clear all data from the lcd display (and tur...

  • Page 52

    X gem-p3200 programming instructions l napco security systems page 52 wi1184b 2/06 [default = blank (•) blank (•) from address 2471-2502; (•)(1) for addresses 2455-2462; (•)(2) for addresses 2463-2470] user area options (address 2455-2502) 1. Select the desired user number. ◄ user no. 1 2 3 4 5 2. E...

  • Page 53

    L napco security systems x gem-p3200 programming instructions page 53 wi1184b 2/06 ezm group options (address 2600-2621) default depends on easy menu question “# of zns in area1 and “# of zns in area2 . For example, if 96 zones are used, then all 22 groups will be automatically enabled. If only 8 zo...

  • Page 54

    X gem-p3200 programming instructions l napco security systems page 54 wi1184b 2/06 area arming options (address 2650-2651) priority area arming: 1. Select the desired arming area. 2. Enable desired options for each priority area by drawing a circle around its corresponding binary data value. Note: n...

  • Page 55

    L napco security systems x gem-p3200 programming instructions page 55 wi1184b 2/06 area output control options (address 2700-2733) area output turns off upon disarm: select options for any of the 5 outputs per area when disarming a particular area. 1. Select the desired option by circling the data v...

  • Page 56

    X gem-p3200 programming instructions l napco security systems page 56 wi1184b 2/06 rf receivers & supervisory timer options (address 3776 & 3760-3775) default number of receivers = 0 left right blank (•) address 3776 number of rf receivers data entries right blank (•) none 1 1 2 2 3 3 4 4 rf receive...

  • Page 57

    L napco security systems x gem-p3200 programming instructions page 57 wi1184b 2/06 external relay control / relays 1-24 (address 3778-3801 & 2800-2895) address 3778 & 2800-2803 (relay/entry 1) 3778 2800 2801 2802 l r l r l r l r l r 2803 address 3779 & 2804-2807 (relay/entry 2) 3779 2804 2805 2806 l...

  • Page 58

    X gem-p3200 programming instructions l napco security systems page 58 wi1184b 2/06 extern a l rela y control step 2: area options: each relay/entry can be assigned to area 1 or 2 or all areas. Select the area from table 2 (shown on next page); enter in corresponding left and right digit address loca...

  • Page 59

    L napco security systems x gem-p3200 programming instructions page 59 wi1184b 2/06 for a desired relay not listed: a. Choose a desired relay, ex: 60 b. Divide it by 16 3 quotient left digit 16 60 48 c remainder right digit 1 quotient left digit 16 20 16 4 remainder right digit table 3 timeouts (alar...

  • Page 60

    X gem-p3200 programming instructions l napco security systems page 60 wi1184b 2/06 extern a l rela y control step 4: event id codes: each relay event can be assigned any of the available event ids from the table. Select 2-digit event id from table 4 (below); enter in corresponding address locations ...

  • Page 61

    L napco security systems x gem-p3200 programming instructions page 61 wi1184b 2/06 extern a l rela y control number of relay board modules (address 3777) [default = blank (•) blank (•)] left right blank (•) address 3777 number of relay board modules data right blank (•) 1 2 3 relay board module(s) n...

  • Page 62

    X gem-p3200 programming instructions l napco security systems page 62 wi1184b 2/06 system reset options (address 4091-4093) clear dealer program (erases dealer program) this erases the dealer program. Use this feature to start a customized default program. Access address 4091, then press the u butto...

  • Page 63

    L napco security systems x gem-p3200 programming instructions page 63 wi1184b 2/06 user progr a m m o de user program mode preliminary information the user program mode is covered in detail in the operating instructions for the keypad in use. Only keypad #1 may be used for programming, however this ...

  • Page 64

    X gem-p3200 programming instructions l napco security systems page 64 wi1184b 2/06 user progr a m mode: a c ce ssing progr a m mode & user codes gem-k2as keypad user01 (direct entry) 123___ programming user codes with gem-k2as keypad to program user codes 1. Enter 2-digit user number (01-32) directl...

  • Page 65

    L napco security systems x gem-p3200 programming instructions page 65 wi1184b 2/06 keypad configuration mode this section will focus on configuring the gem-rp2ase2/gem-k2as, gem-rp3dgtl/gem-k3dgtl, gem- rp4rfc/gem-k4rf, and gem-rp4c/gem-k4 series keypads. If there is more than one keypad in the syst...

  • Page 66

    X gem-p3200 programming instructions l napco security systems page 66 wi1184b 2/06 alphabetical index 1400hz handshake/kissoff, 30 2300hz handshake/kissoff, 30 24 hour zones in area 1, 7, 16 2nd call answering machine override address 2421, 45 2-wire fire zones in area 1, 6, 15 3/1 with extended res...

  • Page 67

    L napco security systems x gem-p3200 programming instructions page 67 wi1184b 2/06 alphabetical index (cont'd) 1024-1027), 34 cs receiver 1 format address 0525, 30 cs receiver 1 options address 0526, 30 cs receiver 2 format address 0550, 30 cs receiver 3 format address 0575, 30 cs receiver format op...

  • Page 68

    X gem-p3200 programming instructions l napco security systems page 68 wi1184b 2/06 alphabetical index (cont'd) enable acm access (address 2423), 51 enable all-zone-in-trouble bypass address 2417, 44 enable ambush in user assignment code type address 3905, 46 enable bell on exit error address 3905, 4...

  • Page 69

    L napco security systems x gem-p3200 programming instructions page 69 wi1184b 2/06 alphabetical index (cont'd) handshake for local telemetry, 34 include sel./grp. Bypass in cond. Closing status address 2417, 44 install more than one keypad, 65 interior 1 normally bypassed address 2419, 44 interior z...

  • Page 70

    X gem-p3200 programming instructions l napco security systems page 70 wi1184b 2/06 alphabetical index (cont'd) start exit delay after ringback address 2418, 44 status report (auto-byp. Zones on clos.) address 2417, 44 sum check, 30 supervised alarm output address 2422, 45 suppress “bypass” icon when...

  • Page 71

    L napco security systems x gem-p3200 programming instructions page 71 wi1184b 2/06 address number location index address 0000 .................................. Exit delay ..................................................................................................................... 28 address...

  • Page 72

    X gem-p3200 programming instructions l napco security systems page 72 wi1184b 2/06 address number location index (cont'd) address 2401 .................................. System delays & timeouts ...................................................................................... 29 address 2402 .....

  • Page 73

    L napco security systems x gem-p3200 programming instructions page 73 wi1184b 2/06 address number location index (cont'd) address 2420 .................................. Telco fail only when armed .................................................................................. 45 address 2420-2422...

  • Page 74

    X gem-p3200 programming instructions l napco security systems page 74 wi1184b 2/06 address number location index (cont'd) address 3777 .................................. Relay board modules .............................................................................................. 61 address 3778...

  • Page 75

    L napco security systems x gem-p3200 programming instructions page 75 wi1184b 2/06 notes.

  • Page 76

    X gem-p3200 programming instructions l napco security systems page 76 wi1184b 2/06 gem-p3200 wiring diagram.