Oceanic OC1 Operating Manual - page 163
163
Data Retention
When the OC1 battery is removed, settings and nitrogen/oxy-
gen calculations for repetitive dives will be retained in volatile
memory until a new battery is installed. You will have the choice
of saving or deleting the data (refer to page 166). The Com-
pass will need to be calibrated after the new battery is installed
(refer to page 146).
All parts needed for the battery change that follows are provid-
ed in the OC1 Battery Kit available at your Authorized Oceanic
Dealer as Oceanic PN 04.6175.35.
OC1 Battery Removal
• There is no need to remove the straps.
• Remove the (4) retaining screws located on the back of the
watch case (Fig. 161) by turning them counter clockwise
with a small flat tip 3mm screw driver.
• Carefully separate the front and back sections (Fig. 162).
The Battery may fall out. DO NOT pry apart with tools.
• Turn the case to one side to drop the Battery into your
hand. If necessary, gently loosen it with the tip of your
finger. DO NOT use tools to pry it out, or short the
positive (+) top of the Battery (Fig. 163a) to the negative
( - ) contact under it.
• Discard the Battery according to local regulations
governing disposal of Lithium batteries.
Fig.161-CASEBACK
Fig.162-SEPARATEFRONT
ANDBACK
Fig.163-BATTINSTALLED
a