Oceanic OC1 Operating Manual - page 85
85
CONSERVATIVE FACTOR (CF)
When the CF is set On, the NDLs which are based on the algorithm selected and used for
Ni/O2 calculations and displays relating to Plan and DTR, will be reduced to the values
available at the altitude level that is 3,000 feet (915 meters) higher. Refer to the NDL
charts on pages 170 and 171.
DEEP STOP (DS)
When the DS selection is set On, it will trigger during NORM No Deco dives when you
descend to 80 FT (24 M) and calculate (and continually update) a Stop Depth equal to
1/2 the Max Depth.
While 10 FT (3 M) deeper than the calculated DS, you will be able to access a DS Pre-
view screen (A 2 sec) that will display the current DS Stop Depth/Time (fixed at 2 min) for
5 seconds then return to the Main.
Upon initial ascent to within 10 FT (3 M) below the calculated Stop Depth, a DS screen
displaying a Stop Depth at 1/2 the Max Depth will appear with a Countdown Timer
beginning at 2:00 (min:sec) and counting down to 0:00.
> If you descend 10 FT (3 M) below, or ascend 10 FT (3 M) above, the calculated Stop
Depth for 10 seconds during the countdown, the No Deco Main will replace the
DS Main display and the DS feature will be disabled for the remainder of that dive.
There is no Penalty if the DS is ignored.
> In the event that you enter Deco, exceeds 190 FT (57 M), or a High O2 condition
(=> 80%) occurs, the DS will be disabled for the remainder of that dive.
> The DS is disabled during a High PO2 Alarm condition (=> Set Point).