13
MANUAL (Manual white balance)
1) Press the Set button to setting Manual white balance
when position the cursor at WHITE BALANCE and
the mode is MANUAL.
2) Press the left, right, up, down direction buttons to
control the Red/Blue gain.
Gain level is indicate from 0 to 20.
After setting, press the Set button to return to main
menu.
Back light compensation
Strong light, such as from a spotlight or window, entering the
scene background causes the lens iris to close, thereby
possibly obscuring desired portions of the scene. Back light
compensation functions automatically adjust the video level so
as to preserve visibility in important sections of the scene.
1) Press the Set button to display the main menu.
2) Position the cursor at BACK LIGHT and press the left
or right button to setting the back light on.
3) Press the left or right button again, back light setting
returns to off.
BLC ZONE SETTING
Backlight control use 6 sensing zones.
The BLC zone setting is activated on the screen by left or
right button to allow the most suitable area to be selected
while observing the monitor. Press the Set button to select
BLC zone when position the cursor at BACK LIGHT and
back light mode is on.
MAIN MENU
LENS
: VIDEO
AGC
: ON
Shutter
: OFF
White Balance
: ATW
➔ Back Light
: ON
Text Display
: OFF
Special Menu
End
BLC ZONE SET
➔ Zone Display
Zone 1
: OFF
Zone 2
: OFF
Zone 3
: OFF
Zone 4
: OFF
Zone 5
: OFF
Zone 6
: OFF
Press SET to View Zone
MANUAL WHITE BALANCE
➔ Red 00
Blue 00
Press SET to Main Menu
Position the cursor at Zone display and press the set
button to view zone.