Pacific Energy BROADWAY Installation And Operating Instructions Manual - Burner Replacement Parts

Manual is about: DIRECT VENT GAS INSERT

Summary of BROADWAY

  • Page 1

    Warning: if the information in this manual is not followed exactly, a fi re or explosion may result causing property damage, personal injury or loss of life. • do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance. • what to do if you smel...

  • Page 2: Contents

    2 161204-24 # 5055.6591 important: when lit for the fi rst time, the appliance will emit a slight odor for a couple of hours. This is due to the curing of paints, sealants and lubricants used in the manufacturing process. This condition is temporary. Open doors and windows to ventilate area. If opti...

  • Page 3: Caution

    3 161204-24 # 5055.6591 caution for your safety - do not install or operate your pacific energy broadway direct vent gas insert without fi rst reading and understanding this manual. Any installation or operational deviation from the following instructions voids the pacific energy warranty and may pr...

  • Page 4: Installation

    4 161204-24 # 5055.6591 installation the broadway direct vent gas insert installation and venting must conform to the current can/cga- b149 installation code (in canada) or the national fuel gas code, ansi z223.1 -1988 (in the usa), and approved per local codes. Only qualifi ed (licensed or trained)...

  • Page 5: Clearances

    5 161204-24 # 5055.6591 clearances the minimum clearances from the appliance to combustible surfaces are shown on fig. #4 and #5. Adequate clearances around air openings and air supplies are required. Fig. # 4 minimum clearances to combustibles: adjacent sidewall: ................. 3.0 in. (76 mm) c...

  • Page 6: Venting

    6 161204-24 # 5055.6591 venting caution: only flex liner kit (mind.Fl25) or an approved gas vent fl ue liner and a vent terminal (mind.Vtterm) is approved for use with this appliance. Also approved for use is simpson dura-vent gs termination kits, both standard vertical termination cap (#980) and th...

  • Page 7: Gas Supply

    7 161204-24 # 5055.6591 the vent terminal must be sealed in place to prevent water from entering the existing chimney. 6) remove the two screws located on top of the unit that retains the vent connector plate on the appliance. Attach ends of the fl ex liners to the collars on top of the connector pl...

  • Page 8: Remote Control Installation

    8 161204-24 # 5055.6591 remote control installation caution: do not connect the batteries to the remote control receiver until the all of the wires are connected to the gas valve as a short circuit could result in damage to the electrical components of the remote control. When installing the remote ...

  • Page 9: Levelling Legs

    9 161204-24 # 5055.6591 levelling legs levelling legs are provided as a convenient means for levelling the appliance when it is installed on an irregular surface. The legs (3" long threaded bolts) can be found packaged inside the appliance. From the underside, thread the legs into the holes into the...

  • Page 10: Brick Panel Installation

    10 161204-24 # 5055.6591 brick panel installation 4 fi xing screws fig # 15 1) remove window (see page 9). 2) remove the 2 screws securing the grate to the mounting brakets (fig # 14). 3) remove the 4 screws securing the fi rebox baffl e to the fi rebox roof (fig # 15). 4) place the fl oor panels on...

  • Page 11

    11 161204-24 # 5055.6591 fig #16 fig #17 fig # 18.

  • Page 12: Log Set Installation

    12 161204-24 # 5055.6591 log set installation the ceramic logs are durable and long lasting when installed properly; however, they are delicate and may be damaged easily if not handled with care. Unpack and inspect log set. There should be a total of 7 logs and one ember bed. Gas and vent connection...

  • Page 13

    13 161204-24 # 5055.6591 step 8: right front chunk pt#: 5097.2614 locate the right front chunk on top of the burner but below the grate. See fi g. # 19h below. Step 5: left front log pt#: 5097.25 fig. # 19e the slot on the underside of the log locates on the pin on the grate. Fig. # 19f step 6: righ...

  • Page 14: Lighting Instructions

    14 161204-24 # 5055.6591 lighting instructions warning: if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instruc...

  • Page 15: Remote Operation

    15 161204-24 # 5055.6591 flashing display timer button remote operation the broadway direct vent insert comes equipped with a thermostatic remote control . Once a pilot light has been established, and the gas control knob turned to the "on" position, the burner may be turned on or off simply with th...

  • Page 16: Blower

    16 161204-24 # 5055.6591 blower installation/repair installation: the blower kit can only be installed when the fi replace is not installed . If not already fi tted unpack and inspect blower kit. 1) remove the left hand side and rear access panles.(fig.#26) 2) secure the speed control junction box t...

  • Page 17

    17 161204-24 # 5055.6591 operation: the variable speed circulating air blower is thermostatically controlled for automatic operation, as well manually with a convenient bypass switch. Automatic: to operate the blower automatically, push the rocker switch to the "auto" position and set the fan speed ...

  • Page 18: Replacement Parts

    18 161204-24 # 5055.6591 all parts may be ordered from your nearest pacifi c energy gas stove dealer. Contact pacifi c energy for the location of the dealer nearest you. Replacement parts see fig. # 29 (when ordering, include part number with description) item description part no. Item description p...

  • Page 19: Surround Replacement Parts

    19 161204-24 # 5055.6591 fig. # 30 all parts may be ordered from your nearest pacifi c energy gas stove dealer. Contact pacifi c energy for the location of the dealer nearest you. Surround replacement parts see fig. # 30 (when ordering, include part number with description) item description part no....

  • Page 20: Burner Replacement Parts

    20 161204-24 # 5055.6591 fig. # 31 all parts may be ordered from your nearest pacifi c energy gas stove dealer. Contact pacifi c energy for the location of the dealer nearest you. Burner replacement parts see fig. # 31 (when ordering, include part number with description) item description part no. I...

  • Page 21: Appendix A

    21 161204-24 # 5055.6591 appendix a 250901 mind-vtterm 5055.658 please refer to the installation instructions provided with the appliance for proper installation. This box contains: direct vent terminal kit mind.Vtterm 1.......Vent terminal 4.......#10 x 5/8" teks screws 6.......#10 x 1 1/2" machine...

  • Page 22

    22 161204-24 # 5055.6591 250901 mind-fla 5055.659 vent terminal flashing installation guide mind.Flash this kit contains: 1......Vent terminal flashing 4......#8 x 1" sheet metal screws installation: 1. Attach the vent terminal to the fl ashing using the 4 screws 2. Attach the fl ashing to the chimn...

  • Page 23: Safety Label

    23 161204-24 # 5055.6591 safety label for use with/ natural gas/ lp-gas/ en case d’emploi avec: du gaz naturel du gaz lp minimum supply pressure / pression minimum d’alimentation: 5.0 in/wc / 5.0 po/c.E. 12.5 in/wc / 12.5 po/c.E. (for the purpose of input adjustment/dans le but de regler l’alimenati...

  • Page 24

    Printed in canada pacifi c energy fireplace products ltd. 2975 allenby road, duncan, bc v9l 6v8 phone: 250-748-1184 web site: http://www.Pacifi cenergy.Net 161204-24 broadway-a # 5055.6591.