Pacific Energy BROADWAY Installation And Operating Instructions Manual - Installation
4
161204-24
# 5055.6591
Installation
The Broadway Direct Vent Gas Insert installation
and venting must conform to the current CAN/CGA-
B149 installation code (in Canada) or the National
Fuel Gas Code, ANSI Z223.1 -1988 (in the USA), and
approved per local codes. Only qualifi ed (licensed
or trained) personnel should install this product.
Existing Fireplace
(Masonry or Factory Built)
The Broadway Direct Vent Gas Insert is designed
to be installed into a masonry or a factory built zero
clearance fi replace. The masonry fi replace must be
built according to the requirements of the Standards
for Chimneys, Fireplaces, Vents and Solid Fuel Burning
Appliances, NFPA 211 (Latest Edition) or applicable
National, Provincial, State or local codes. The factory
built zero clearance fi replace and its chimney must be
certifi ed and meet applicable National, Provincial, State
or local codes.
In order to suffi ciently accommodate the Broadway
Direct Vent Gas Insert, the minimum size of the fi replace
should be 31 inches wide, 20 3/4 inches high and 18
inches deep (see Fig. #2).
The fi replace and its chimney should be swept and
inspected. The existing fi replace damper (if present)
should be locked open or removed completely if the
opening is too small for two 3" fl ue liners to pass
through.
Fig. # 3
Fig. # 2