    040515-24 neo16 5055.700 installation and operating instructions safety notice if this stove is not properly installed, a house fi re may result. For your safety, follow the installation instructions. Contact local building or fi re officials about restrictions and installation inspection requiremen...

  • Page 2: Contents

    2 040515-24 ©pacific energy fireplace products ltd. Please save these instructions this manual describes the installation and operation of the pacifi c energy, neo 1.6 freestanding wood heater. This heater meets the 2015 u.S. Environmental protection agency's crib wood emission limits for wood heate...

  • Page 3

    040515-24 3 ©pacific energy fireplace products ltd. Chimney smoke and creosote formation when wood is burned slowly, it produces tar and other or- ganic vapours, which combine with expelled moisture to form creosote. The creosote vapours condense in the relatively cool chimney fl ue of a slow burnin...

  • Page 4

    4 040515-24 ©pacific energy fireplace products ltd. Caution: never use gasoline, gasoline type lantern fuel, kerosene, charcoal lighter fl uid or similar liquids to start or "freshen up" a fi re in this heater. Keep all such liquids well away from the heater while it is in use. Caution: hot while in...

  • Page 5

    040515-24 5 ©pacific energy fireplace products ltd. 2. Too much draft may cause excessive temperatures in the appliance. An uncontrollable burn or a glowing red stove part or chimney indicates excessive draft. 3. Inadequate draft may cause backpuffing into the room and plugging of the chimney. Smoke...

  • Page 6

    6 040515-24 ©pacific energy fireplace products ltd. 1. Burn wood only, dry and well seasoned. The denser or heavier the wood when dry, the greater its heat value. This is why hardwoods are generally preferred. Green or wet wood will cause a rapid buildup of creosote. If you feel it is necessary to b...

  • Page 7

    040515-24 7 ©pacific energy fireplace products ltd. Maintenance checks check the following parts for damage such as cracks, excessive corrosion, burned out sections and excessive warping: (see website for descriptions and more detail) some warping of the baffle is normal(up to 1/4” or .65cm). Replac...

  • Page 8

    8 040515-24 ©pacific energy fireplace products ltd. 36 15/16" 938mm 36" 914mm 20 1/8" 511mm 17 7/16" 443mm 6" 152mm 27 1/8" 689mm neo 1.6 dimensions crate removal 1) carefully remove wood top and supports. 2) remove plastic cover. 3) using a 7/16"(12mm) wrench, remove lag bolts that secure hold down...

  • Page 9

    040515-24 9 ©pacific energy fireplace products ltd. 8" [203mm] 16" [406mm] 8" [203mm] canada only floor protector the stove may be installed on a combustible fl oor provided noncombustible ember protection is used. This protection must extend as follows: in canada: 18" (457 mm) on the fi ring side a...

  • Page 10

    10 040515-24 ©pacific energy fireplace products ltd. Warning: under no circumstances is this heater to be installed in a makeshift or "temporary" manner. It may be fi red only after the following conditions have been met. * do not attempt to connect this heater to any air distribution duct. * outsid...

  • Page 11: Mobile Home

    040515-24 11 ©pacific energy fireplace products ltd. 18" 457mm 12" 305mm 25 1/2” 673mm 20" 508mm 8" 203mm 11" 279mm 5" 127mm 15" 381mm 3" 8" 203mm 3" 76mm 8" 203mm 8" 203mm 21 1/2" 549mm 8" 203mm 11" 279mm 5" 127mm 21 1/2" 549mm 15" 381mm 21 1/2" 549mm 8" 203mm 11" 279mm 5" 127mm 3" 76mm 3" 76mm mob...

  • Page 12

    12 040515-24 ©pacific energy fireplace products ltd. Fig. #8 chimney roof fl ashing storm collar * 4" diameter air inlet with rodent screen * if the crawl space is well ventilated it is not necessary to extend air inlet to outside spark arrestor rain cap radiation shield chimney connector chimney su...

  • Page 13

    040515-24 13 ©pacific energy fireplace products ltd. Fig. #9 chimney * 4" diameter air inlet with rodent screen * if the crawl space is well ventilated it is not necessary to extend air inlet to outside concrete cap chimney connector 12"(305mm) minimum fi rst section of pipe. Fireclay flue liner min...

  • Page 14

    14 040515-24 ©pacific energy fireplace products ltd. The optional blower kit (wodc.Blow) is equipped with a three prong power cord and may be installed at any time. Follow installation instructions supplied with the kit. Route power supply cord away from heater. Electrical rating: 115 volts a.C., 60...

  • Page 15

    040515-24 15 ©pacific energy fireplace products ltd. Troubleshooting problem cause cure glass is dirty 1. Wood is wet - use dry wood 2. Turning down air control - do not turn down until or damper too soon a) there is a good bed of coals b) the wood is charred 3. Draft too low - improper chimney heig...

  • Page 16

    16 040515-24 ©pacific energy fireplace products ltd. Replacement parts - neo 1.6 (when ordering, include part number with description) item description part no. Item description part no. 2............ Embossed panel set .................... Ne16.78375xx 3............ Door catch ........................

  • Page 17

    040515-24 17 ©pacific energy fireplace products ltd. Operating tips 1. Always use dry, seasoned fi rewood, up to 18"(457mm) long. Load wood, a mixture of large and small pieces, on top of a good ash base (1"(25mm) minimum). 2. Operate on a medium to high setting, for up to 1 hour from cold start. Af...

  • Page 18

    18 040515-24 ©pacific energy fireplace products ltd. Item/ article dimensions part number/ numÉro de piÈce a 1 1/2” x 4 1/2” x 1 1/4” (39 mm x 115 mm x 32 mm) 248.0 b 3” x 4 1/2” x 1 1/4” (77 mm x 115 mm x 32 mm) 247.0 d 9” x 4 1/2” x 1 1/4” (230 mm x 115 mm x 32 mm) 5096.99 neo 1.6 firebrick instal...

  • Page 19

    040515-24 19 ©pacific energy fireplace products ltd. Warranty information pacifi c energy limited lifetime warranty wood products pacifi c energy extends the following warranty coverage to the original registered purchaser of the product: ltd lifetime coverage (10 years) limited lifetime coverage is...

  • Page 20

    20 040515-24 ©pacific energy fireplace products ltd..

  • Page 21

    040515-24 21 ©pacific energy fireplace products ltd..

  • Page 22

    22 040515-24 ©pacific energy fireplace products ltd..

  • Page 23: Caution

    040515-24 23 ©pacific energy fireplace products ltd. Label a. 12 in. / 305 mm 12 in. / 305 mm b. 12 in. / 305 mm 12 in./305 mm c. 8 in. / 203 mm 8 in. / 203 mm d. 22.5 in. / 572 mm 22.5 in. / 572 mm e. 15 in. / 381 mm 15 in. / 381 mm f . 17 in. / 432 mm 17 in. / 432 mm a. 8 in. / 203 mm 8 in. / 203 ...

  • Page 24

    ©pacific energy fireplace products ltd. Pacific energy fireplace products ltd. 2975 allenby rd., duncan, b.C. V9l 6v8 for technical support, please contact your retailer. Web site: http://www.Pacifi cenergy.Net printed in canada.