MAINS / LINE FUSE.
A Mains / Line fuse is fitted within the IEC Mains / Line socket on the rear of the amplifier. A small
draw at the bottom of this socket may be removed ( after the IEC plug is removed ) by levering it out with
a flat blade screw driver. The fuse fitted should be rated at no greater than 5 Amps Fast-Blow. A spare
fuse is located within the draw.
In the unusual event that this fuse should blow, you must first establish the cause of this failure, cure the
fault and then replace the fuse with one of the same type.
DO NOT FIT A FUSE WITH A HIGHER RATING without consulting your
PLINIUS
dealer first.
In the event that your Mains / Line voltage is different to that printed on the back of the P7, it may altered
by a suitably qualified or experienced person.
There are only two options, 110V - 120V or 220V - 240V Operation
Consult your PLINIUS dealer for any changes that may be necessary.
RAIL FUSE
At the rear of the P7 there are four fuses, for each voltage rail of each channel.
Should one of these fail, it will be indicated by the adjacent LED, which will glow
( while the power is still turned on ) to indicate a fuse failure.
Before replacing the fuse, first find out what caused the failure, cure the fault, or if in doubt consult your
PLINIUS
dealer.
To remove the fuse, push the holder in slightly, and turn counter-clockwise, the replacement fuse should
be no greater than 5 Amps Fast-Blow.