PS Audio Power Plant P1000 Operation Manual - page 4
1. Filtered AC zone
One Power Port duplex receptacle provides two
outlets for filtered AC. The filtered AC zone will
pass as much current as a 15 amp wall receptacle
can provide, up to 1800 watts.
The controls for frequency, voltage, and MultiWave
setting do not affect the Filtered AC zone outlets.
This power zone should be used for very high
current draw products which require more power
than the Regenerated AC zone will provide.
The Filtered AC zone will always pass power
regardless of the front panel power status or fault
status.
2. PS Bus
The P1000 comes equipped with a built in PS
Bus. The PS Bus allows other PS Audio products
equipped with a PS Bus to communicate via stan-
dard RJ11 “twisted end” crossover cable.
3 & 5. Main and Protection Fuses
The main fuse is a 15 Amp slow blow. The pro-
tection fuse is a 1 Amp fast blow. Both can be
removed by inserting a flat device into the fuse
holder and twisting counter-clockwise.
4. IEC AC Power Inlet
15 Amp IEC standard male socket.
6. Regenerated AC zone
Four Power Port duplex receptacles provide eight
outlets for regenerated AC. The Regenerated AC
zone will produce up to 1000 watts peak power
depending on the type of load.
The Regenerated AC zone will only pass power if
the front panel power switch is on and the P1000
is not in a fault status mode.
MultiWave II and the associated TubeWave and
AutoWave waveforms are only available through
the Regenerated AC Zone outlets.
4
Rear Panel Layout