Quadra-Fire MTV-E2-CSB Owner's Manual

Summary of MTV-E2-CSB

  • Page 1

    1 7080-132d october 27, 2014 o-t l tested and listed by portland oregon usa omni-test laboratories, inc. C us mt. Vernon e2 pellet stove model(s): mtv-e2-csb mtv-e2-mbk mtv-e2-pft mtv-e2-pdb mtv-e2-pbk mtv-e2-pmh please read this entire manual before installation and use of this pellet fuel-burning ...

  • Page 2: Caution:

    2 7080-132d october 27, 2014 mt. Vernon e2 b. Sample of serial number / safety label location: back of stove serial no. Model name test lab & report no. Mfg. Date hot while in operation do not touch, keep children, clothing and furniture away. Contact may cause skin burns. See nameplate and instruct...

  • Page 3

    October 27, 2014 7080-132d 3 mt. Vernon e2 table of contents safety alert key: • danger!Indicates a hazardous situation which, if not avoided will result in death or serious injury. • warning! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • caution!In...

  • Page 4

    4 7080-132d october 27, 2014 mt. Vernon e2 hearth & home technologies inc. Limited lifetime warranty hearth & home technologies inc., on behalf of its hearth brands (”hht”), extends the following warranty for hht gas, wood, pellet, coal and electric hearth appliances that are purchased from an hht a...

  • Page 6

    6 7080-132d october 27, 2014 mt. Vernon e2 d. Quick start guide ru n se t up pr im e 1. Empty firebox 2. Add pellets and close lid 3. Turn dial to off 4. Plug in the appliance • exhaust blower will run for about 45 seconds (wait for it to stop before priming) • green light will start fl ashing 5. Pu...

  • Page 7

    October 27, 2014 7080-132d 7 mt. Vernon e2 *btu will vary, depending on the type of fuel you use in your appliance. Consult your quadra-fire dealer for best results. C. Glass specifi cations this stove is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please contact your...

  • Page 8: User Guide

    8 7080-132d october 27, 2014 mt. Vernon e2 user guide 2 operating instructions a. Fire safety to provide reasonable fi re safety, the following should be given serious consideration: • install at least one smoke detector on each fl oor of your home. • install at least one carbon monoxide detector on...

  • Page 9

    October 27, 2014 7080-132d 9 mt. Vernon e2 figure 9.1 hot while in operation. Keep children, clothing and furniture away. Contact may cause skin burns. Caution • burning pellets longer than 1-1/2 inches (38mm) can cause an inconsistent fuel feed rate and/or missed ignitions or feed jams. Storage • w...

  • Page 10

    10 7080-132d october 27, 2014 mt. Vernon e2 k. Fire characteristics the overall height of the fl ame will vary throughout the burn for a couple of reasons: 1) the fl ame will vary based on type of fuel or batch of fuel. 2) the unit adjusts the burn rate according to the dial set- ting – the further ...

  • Page 11

    October 27, 2014 7080-132d 11 mt. Vernon e2 led color no. Of flashes between pauses description notes green steady on while priming feed tube (max time 2 min utes) feed motor is running continuously. (priming the feed tube) when priming the feed system and fi lling the fi repot, do not overfill fire...

  • Page 12

    12 7080-132d october 27, 2014 mt. Vernon e2 n. Restarting the appliance restart process 1. When the unit has run out of fuel and the “empty hopper” error code illuminates, add pellet fuel to the hopper. 2. Dump the ashes and clinkers built up in the fi repot by pulling the ash dump removal handle ou...

  • Page 13

    October 27, 2014 7080-132d 13 mt. Vernon e2 remote thermostat: fahrenheit / celsius 1. Temperatures will show either °f or °c displayed on the screen. 2. Press both “up” and “down” arrow keys simultane- ously. The display should change from fahrenheit to celsius or vice-versa. Remote thermostat: swi...

  • Page 14

    14 7080-132d october 27, 2014 mt. Vernon e2 s. Frequently asked questions what causes my glass to become dirty? If the glass has white ash build up it is normal and the glass should be cleaned. If it is a black soot build up airfl ow through the unit may be restricted. The most often cause is overdu...

  • Page 15

    October 27, 2014 7080-132d 15 mt. Vernon e2 3 maintenance and service b. Quick reference maintenance chart notice: these are recommendations. When burning high ash content pellet fuel or a corn/pellet mix you may need to clean the fi repot several times a day. Clean the stove and fi repot more frequ...

  • Page 16

    16 7080-132d october 27, 2014 mt. Vernon e2 figure 16.1 - firepot with large clinker clinker figure 16.2 c. General maintenance and cleaning 1. Cleaning firepot using lever • frequency: daily or as needed* • by: homeowner *when burning high ash content pellet fuel or a pellet/corn mix you may need t...

  • Page 17

    October 27, 2014 7080-132d 17 mt. Vernon e2 figure 17.2 - example of a dirty heat exchanger figure 17.3 shop vacuum and micro cleaning kit examples - items that can be purchased at local hardware stores. Figure 17.4 figure 17.1 exhaust exits must be thoroughly cleaned. Each exit is approximately 4 i...

  • Page 18

    18 7080-132d october 27, 2014 mt. Vernon e2 figure 18.1 ash dump lever handle glass assembly with care. When cleaning glass door: • avoid striking, scratching or slamming glass. Caution • do not clean glass when hot. • do not use abrasive cleaners. • use a hard water deposit glass cleaner on white f...

  • Page 19

    October 27, 2014 7080-132d 19 mt. Vernon e2 figure 19.1 note • this unit is required to be cleaned frequently because soot creosote and ash may accumulate. 10. Cleaning convection blower requires no lubrication • frequency: see chart on page 15 • by: homeowner a. Be sure the appliance is allowed to ...

  • Page 20

    20 7080-132d october 27, 2014 mt. Vernon e2 baffle latches insert flat head screw driver into “v” section and push down and the bottom of the latch will fall forward off of post locating ears - 1 on each side. Fit behind bottom edge. Figure 20.2 figure 20.3 pellets back-up in feed tube firepot overf...

  • Page 21

    October 27, 2014 7080-132d 21 mt. Vernon e2 figure 21.1 h. Convection blower replacement 1. Follow the proper shut down procedures. 2. Remove the left side panel by loosening the 2 screws using a phillips head screw driver or wrench. Figure 21.1 3. Remove two lower sheet metal screws from the back p...

  • Page 22

    22 7080-132d october 27, 2014 mt. Vernon e2 i . Combustion/exhaust blower replacement 1. Follow the proper shut down procedures. 2. Remove the right side panel by loosening the 2 screws using a phillips head screw driver or wrench. Figure 22.1. 3. It is not necessary or recommended to remove the hou...

  • Page 23

    October 27, 2014 7080-132d 23 mt. Vernon e2 with proper installation, operation, and maintenance your appliance will provide years of trouble-free service. If you do experience a prob- lem, this troubleshooting guide will assist a qualifi ed service person in the diagnosis of a problem and the corre...

  • Page 24

    24 7080-132d october 27, 2014 mt. Vernon e2 symptom possible cause corrective action appliance starts and stops frequently when operating in the remote mode area where the thermostat is placed affects temperature. Check thermostat proximity to doors and windows thermostat located in tight spaces eff...

  • Page 25

    October 27, 2014 7080-132d 25 mt. Vernon e2 symptom possible cause corrective action large, lazy fl ame (orange color) with black ash / soot buildup on glass dirty appliance or venting clean unit including the fi repot, exhaust path, and venting system poor fuel quality, high ash content. Purge old ...

  • Page 26

    26 7080-132d october 27, 2014 mt. Vernon e2 following correction of any alarm, turn the dial control to the off position, wait 10 seconds and turn back to desired setting or unplug the unit, wait 10 seconds then restore power. Alarm (led flashing red) possible cause corrective action 1 red flash: em...

  • Page 27

    October 27, 2014 7080-132d 27 mt. Vernon e2 exhaust temperature serial port (service only) pot set temp vcc pot set temp gnd pot set temp sig pot feed adjust vcc pot feed adjust gnd pot feed adjuts sig led red led amber led green fuse m m m 110 v line neutral igniter feed motor exhaust blower convec...

  • Page 28: Mt Vernon E2

    28 7080-132d october 27, 2014 mt. Vernon e2 service parts r mt vernon e2 beginning manufacturing date: feb 2014 ending manufacturing date: active pellet stove mtv-e2-csb, mtv-e2-mbk, mtv-e2-pbk, mtv-e2-pdb, mtv-e2-pft, mtv-e2-pmh part number list on following page. 09/14 1 2 3 4 5 6 7 8 9 10 11 12 1...

  • Page 29: Mt Vernon E2

    October 27, 2014 7080-132d 29 mt. Vernon e2 service parts r mt vernon e2 beginning manufacturing date: feb 2014 ending manufacturing date: active important: this is dated information . Parts must be ordered from a dealer or distributor. Hearth and home technologies does not sell directly to consumer...

  • Page 30: Mt Vernon E2

    30 7080-132d october 27, 2014 mt. Vernon e2 service parts r mt vernon e2 beginning manufacturing date: feb 2014 ending manufacturing date: active important: this is dated information . Parts must be ordered from a dealer or distributor. Hearth and home technologies does not sell directly to consumer...

  • Page 31: Mt Vernon E2

    October 27, 2014 7080-132d 31 mt. Vernon e2 service parts r mt vernon e2 beginning manufacturing date: feb 2014 ending manufacturing date: active important: this is dated information . Parts must be ordered from a dealer or distributor. Hearth and home technologies does not sell directly to consumer...

  • Page 32: Mt Vernon E2

    32 7080-132d october 27, 2014 mt. Vernon e2 service parts r mt vernon e2 beginning manufacturing date: feb 2014 ending manufacturing date: active important: this is dated information . Parts must be ordered from a dealer or distributor. Hearth and home technologies does not sell directly to consumer...

  • Page 33: Mt Vernon E2

    October 27, 2014 7080-132d 33 mt. Vernon e2 service parts r mt vernon e2 beginning manufacturing date: feb 2014 ending manufacturing date: active important: this is dated information. Parts must be ordered from a dealer or distributor. Hearth and home technologies does not sell directly to consumers...

  • Page 34

    34 7080-132d october 27, 2014 mt. Vernon e2.

  • Page 35

    October 27, 2014 7080-132d 35 mt. Vernon e2.

  • Page 36

    36 7080-132d october 27, 2014 do not discard this manual caution • important operating and maintenance instruc- tions included. • leave this manual with party responsible for use and operation. • read, understand and follow these instruc- tions for safe installa- tion and operation. Do not discard c...