Quadra-Fire MTV-E2-CSB Owner's Manual - page 20
20
7080-132D
October 27, 2014
MT. VERNON E2
Baffle
Latches
Insert flat head screw driver into “V”
section and push down and the bottom
of the latch will fall forward off of post
Locating ears - 1 on
each side. Fit behind
bottom edge.
Figure 20.2
Figure 20.3
Pellets Back-Up
in Feed Tube
Firepot Overfills
Ash Build-Up in Firebox
Figure 20.1
F. Baffl e Removal
1. The appliance must be in complete shutdown, com-
pletely cool and the exhaust blower off.
2. Open
door.
3. The
baffl e is located at the top inside of fi rebox.
4. Remove
baffl e by placing a fl at head screw driver into
the slot of the latches located in the upper corners and
rotate down. The bottom of the latch will fall forward off
of the post. Lift the baffl e up and then out toward you.
Figure 20.2
5. To replace the baffl e, place the 2 locating ears behind
the bottom edge and tilt the baffl e up and into place.
6. The
baffl e must be centered in the fi rebox before
latching it in place. If it is not centered the latch will slip
between the baffl e and side of the fi rebox instead of
latching properly.
7. The bottom of the latches will fi t over the posts. Using
a screwdriver, rotate the top of the latch up to lock latch
into place.
WARNING
Cast iron is a very heavy material. The baffl e is
made of cast iron and therefore is heavy and awkward
at times to maneuver. Clear and prepare your work
area before you begin.
• Glass is 5mm thick high temperature heat-re-
sistant ceramic glass.
• DO NOT REPLACE with any other material.
• Alternate material may shatter and cause
injury.
WARNING
G. Glass Replacement
1. Swing open the face and remove the door from the
appliance by lifting the door off of the hinge pins and lay
on a fl at surface face down.
2. Using a Phillips head screw driver, remove 4 screws, 2
on the top and 2 on the bottom. Remove metal bracket
and then remove the glass. Figure 20.3
3. Replace with new glass with gasket.
4. Re-attach metal bracket with 4 screws.
5. Re-install door over hinge pins and close face.
E. High Ash Fuel Content Maintenance
• Frequency: Daily
• By: Homeowner
If the ash build-up exceeds the half way point in the fi repot or
if clinkers are adhering to the sides of the fi repot, the fi repot
fl oor is not being cycled enough.
WARNING
Risk of Fire and Smoke!
• High ash fuels or lack of maintenance can cause
fi repot to overfi ll. Follow proper shutdown proce-
dure if ash buildup exceeds half way point in fi repot.
• Failure to do so could result in smoking, sooting and pos-
sible hopper fi res.