Quadra-Fire MTV-E2-CSB Owner's Manual

Summary of MTV-E2-CSB

  • Page 1

    1 7080-132b march 14, 2014 o-t l tested and listed by portland oregon usa omni-test laboratories, inc. C us mt. Vernon pellet stove e2 model(s): mtv-e2-csb mtv-e2-mbk mtv-e2-pft mtv-e2-pdb mtv-e2-pbk mtv-e2-pmh please read this entire manual before installation and use of this pellet fuel-burning ro...

  • Page 2: Caution:

    2 7080-132b march 14, 2014 mt. Vernon e2 b. Sample of serial number / safety label location:backofstove serial no. Model name testlab& report no. Mfg. Date hot while in operation do not touch, keep children, clothing and furniture away. Contact may cause skin burns. See nameplate and instructions. C...

  • Page 3

    March 14, 2014 7080-132b 3 mt. Vernon e2 table of contents safety alert key: • danger!Indicates a hazardous situation which, if not avoided will result in death or serious injury. • warning! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • caution!Indi...

  • Page 4

    4 7080-132b march 14, 2014 mt. Vernon e2 page 54 7022-122 january 19, 2011 r castile pellet insert 4021-645c 12-29-10 page 1 of 2 hearth & home technologies inc. Limited lifetime warranty hearth & home technologies inc., on behalf of its hearth brands (”hht”), extends the following warranty for hht ...

  • Page 5

    March 14, 2014 7080-132b 5 mt. Vernon e2 r january 19, 2011 7022-122 page 55 castile pellet insert 4021-645c 12-29-10 page 2 of 2 warranty conditions: ...

  • Page 6: Quick Start Guide

    6 7080-132b march 14, 2014 mt. Vernon e2 d. Quick start guide november 21, 2013 quick start guide *before you plug in this appliance, follow these instructions* ru n set u p pr im e 1. Empty firebox 2. Add pellets and close lid 3. Turndialtooff 4. Plug in the appliance • exhaust blower will run for ...

  • Page 7

    March 14, 2014 7080-132b 7 mt. Vernon e2 *btuwillvary,dependingonthetypeoffuelyouuseinyour appliance. Consult your quadra-fire dealer for best results. C.Glassspecifications thisstoveisequippedwith5mmceramicglass.Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement g...

  • Page 8: User Guide

    8 7080-132b march 14, 2014 mt. Vernon e2 user guide 2 operating instructions a. Fire safety to provide reasonable fire safety, the following should be givenseriousconsideration: • installatleastonesmokedetectoroneachfloorofyour home. • installatleastonecarbonmonoxidedetectoroneachfloor of your home....

  • Page 9

    March 14, 2014 7080-132b 9 mt. Vernon e2 figure 9.1 hot while in operation. Keep children, clothing and furniture away. Contact may cause skin burns. Caution e. Before your first fire 1. First, make sure your appliance has been properly installed and that all safety requirements have been met. Paypa...

  • Page 10

    10 7080-132b march 14, 2014 mt. Vernon e2 k. Fire characteristics theoverallheightoftheflamewillvarythroughouttheburn foracoupleofreasons: 1) theflamewillvarybasedontypeoffuelorbatchof fuel. 2) theunitadjuststheburnrateaccordingtothedialset- ting–thefurtherthedialisrotatedclockwisethehigher theflame...

  • Page 11

    March 14, 2014 7080-132b 11 mt. Vernon e2 led color no. Of flashes between pauses description notes green steadyonwhile priming feed tube (max time 2 min utes) feed motor is running continuously. (priming the feed tube) whenprimingthefeedsystemandfillingthefirepot,do notoverfillfirepotforignition . ...

  • Page 12

    12 7080-132b march 14, 2014 mt. Vernon e2 n. Restarting the appliance restart process 1. When the unit has run out of fuel and the “empty hopper”errorcodeilluminates,addpelletfueltothe hopper. 2. Dumptheashesandclinkersbuiltupinthefirepotby pulling the ash dump removal handle out several times. Make...

  • Page 13

    March 14, 2014 7080-132b 13 mt. Vernon e2 remote thermostat: fahrenheit / celsius 1. Temperatureswillshoweither°for°cdisplayedonthe screen. 2. Press both“up”and“down”arrowkeyssimultane- ously. Thedisplayshouldchangefromfahrenheitto celsius or vice-versa. Remote thermostat: swing 1. Theswingtemperatu...

  • Page 14

    14 7080-132b march 14, 2014 mt. Vernon e2 s. Frequently asked questions what causes my glass to become dirty? If the glass has white ash build up it is normal and the glassshouldbecleaned.Ifitisablacksootbuildupairflow throughtheunitmayberestricted.Themostoftencauseis overdue maintenance and cleanin...

  • Page 15

    March 14, 2014 7080-132b 15 mt. Vernon e2 3 maintenance and service b. Quick reference maintenance chart notice:thesearerecommendations.Cleanmorefrequentlyifyouencounterheavybuild-upof ash at the recommended interval or you see soot coming from the vent. Notproperly cleaningyourapplianceonaregularba...

  • Page 16

    16 7080-132b march 14, 2014 mt. Vernon e2 figure 16.1 - firepot with large clinker clinker figure 16.2 c. General maintenance and cleaning 1. Cleaning firepot using lever • frequency: daily • by: homeowner a. Be sure the appliance is allowed to cool. B. Opencastfaceofappliance c. Pullfirepotfloorcle...

  • Page 17

    March 14, 2014 7080-132b 17 mt. Vernon e2 figure 17.2 - example of a dirty heat exchanger figure 17.3 shop vacuum and micro cleaning kit examples - items that can be purchased at local hardware stores. Figure 17.4 figure 17.1 exhaust exits must be thoroughly cleaned. Each exit is approximately 4 inc...

  • Page 18

    18 7080-132b march 14, 2014 mt. Vernon e2 figure 18.1 ash dump lever handle glass assembly with care. When cleaning glass door: • avoidstriking,scratchingorslamming glass. Caution • donotcleanglasswhenhot. • donotuseabrasivecleaners. • useahardwaterdepositglasscleaneronwhitefilm. Refer to maintenanc...

  • Page 19

    March 14, 2014 7080-132b 19 mt. Vernon e2 figure 19.1 note • this unit is required to be cleaned frequently because soot creosote and ash may accumulate. 10. Cleaning convection blower requires no lubrication • frequency: see chart on page 15 • by: homeowner a. Be sure the appliance is allowed to co...

  • Page 20

    20 7080-132b march 14, 2014 mt. Vernon e2 baffle latches insert flat head screw driver into “v” section and push down and the bottom of the latch will fall forward off of post locating ears - 1 on each side. Fit behind bottom edge. Figure 20.2 figure 20.3 pellets back-up in feed tube firepot overfil...

  • Page 21

    March 14, 2014 7080-132b 21 mt. Vernon e2 figure 21.1 h. Convection blower replacement 1. Follow the proper shut down procedures . 2. Remove the left side panel by loosening the 2 screws using a phillips head screw driver or wrench. Figure 21.1 3. Remove two lower sheet metal screws from teh back pa...

  • Page 22

    22 7080-132b march 14, 2014 mt. Vernon e2 i . Combustion/exhaust blower replacement 1. Follow the proper shut down procedures . 2. Remove the right side panel by loosening the 2 screws using a phillips head screw driver or wrench. Figure 22.1. 3. It is not necessary or recommended to remove the hous...

  • Page 23

    March 14, 2014 7080-132b 23 mt. Vernon e2 with proper installation, operation, and maintenance your appliance will provide years of trouble-free service. If you do experience a prob- lem,thistroubleshootingguidewillassistaqualifiedservicepersoninthediagnosisofaproblemandthecorrectiveactiontobetaken....

  • Page 24

    24 7080-132b march 14, 2014 mt. Vernon e2 symptom possible cause corrective action appliance starts and stops frequently when operating in the remote mode area where the thermostat is placed affects temperature. Check thermostat proximity to doors and windows thermostatlocatedintightspaces effecting...

  • Page 25

    March 14, 2014 7080-132b 25 mt. Vernon e2 symptom possible cause corrective action large,lazyflame(orangecolor)with black ash / soot buildup on glass dirty appliance or venting cleanunitincludingthefirepot, exhaust path, and venting system poor fuel quality, high ash content. Purge old fuel and use ...

  • Page 26

    26 7080-132b march 14, 2014 mt. Vernon e2 following correction of any alarm, turn the dial control to the off position, wait 10 seconds and turn back to desired setting or unplug the unit, wait 10 seconds then restore power. Alarm (led flashing red) possible cause corrective action 1redflash:emptyho...

  • Page 27

    March 14, 2014 7080-132b 27 mt. Vernon e2 exhaust temperature serial port (service only) pot set temp vcc pot set temp gnd pot set temp sig pot feed adjust vcc pot feed adjust gnd pot feed adjuts sig led red led amber led green fuse m m m 110 v line neutral igniter feed motor exhaust blower convecti...

  • Page 28: Mt Vernon E2

    28 7080-132b march 14, 2014 mt. Vernon e2 service parts r mt vernon e2 beginning manufacturing date: dec 2013 ending manufacturing date: active pellet stove mtv-e2-csb, mtv-e2-mbk, mtv-e2-pbk, mtv-e2-pdb, mtv-e2-pft, mtv-e2-pmh part number list on following page. 11/13 1 2 3 4 5 6 7 8 9 10 11 12 13 ...

  • Page 29: Mt Vernon E2

    March 14, 2014 7080-132b 29 mt. Vernon e2 service parts r mt vernon e2 beginning manufacturing date: dec 2013 ending manufacturing date: active important: this is dated information . Parts must be ordered from a dealer or distributor. Hearth and home technologies does not sell directly to consumers ...

  • Page 30: Mt Vernon E2

    30 7080-132b march 14, 2014 mt. Vernon e2 service parts r mt vernon e2 beginning manufacturing date: dec 2013 ending manufacturing date: active important: this is dated information . Parts must be ordered from a dealer or distributor. Hearth and home technologies does not sell directly to consumers ...

  • Page 31: Mt Vernon E2

    March 14, 2014 7080-132b 31 mt. Vernon e2 service parts r mt vernon e2 beginning manufacturing date: dec 2013 ending manufacturing date: active important: this is dated information . Parts must be ordered from a dealer or distributor. Hearth and home technologies does not sell directly to consumers ...

  • Page 32: Mt Vernon E2

    32 7080-132b march 14, 2014 mt. Vernon e2 service parts r mt vernon e2 beginning manufacturing date: dec 2013 ending manufacturing date: active important: this is dated information . Parts must be ordered from a dealer or distributor. Hearth and home technologies does not sell directly to consumers ...

  • Page 33: Mt Vernon E2

    March 14, 2014 7080-132b 33 mt. Vernon e2 service parts r mt vernon e2 beginning manufacturing date: dec 2013 ending manufacturing date: active important:thisisdatedinformation.Partsmustbeorderedfromadealerordistributor. Hearth and home technologies does not sell directly to consumers. Provide model...

  • Page 34

    34 7080-132b march 14, 2014 mt. Vernon e2.

  • Page 35

    March 14, 2014 7080-132b 35 mt. Vernon e2.

  • Page 36

    36 7080-132b march 14, 2014 do not discard this manual caution • importantoperatingand maintenance instruc- tionsincluded. • leavethismanualwith partyresponsibleforuse andoperation. • read,understandand follow these instruc- tionsforsafeinstalla- tionandoperation. Do not discard contact information ...