Quadra-Fire MTV-E2-CSB Owner's Manual - page 26
26
7080-132B
March 14, 2014
MT. VERNON E2
Following correction of any Alarm, turn the dial control to the OFF position, wait 10 seconds and turn back to
desired setting OR unplug the unit, wait 10 seconds then restore power.
Alarm
(LED Flashing RED)
Possible Cause
Corrective Action
1RedFlash:EmptyHopperAlarm
Hopper empty
Fill the hopper
Auger jam
Inspect the feed tube for jams
Vacuum switch not closing
Makesurefireboxdoorisshut,
vacuum hose is connected to switch
and drop tube, wire connectors are
connected to vacuum switch, control
board, hopper switch, and safety
snap disc.
Hopper lid open
Close the hopper lid
Exhaust probe does not sense tem-
perature
Secure the exhaust probe keeping
its wire away from hot surfaces and
clean the exhaust plenum
Snap disc tripped
Reset snap disc
Exhaust probe not attached to
exhaust blower properly
Secure exhaust probe to exhaust
blowerhousing–keepingitswire
away from hot surfaces
Exhaust path is dirty
Cleanunitincludingthefirepot,
exhaust path, and venting system
2RedFlashes:ExhaustProbeFail
Not connected to the control board
Connect terminal end to control board
Failed component
Replaceexhaustprobe–securingit
toexhaustblowerhousing–keeping
wire away from hot surfaces
4RedFlashes:MissedIgnition
Hopper empty
Fill the hopper
Feed motor doesn’t turn
Inspect feed motor circuit (hopper lid
must be closed, vacuum switch must
be closed, snap disc closed, and feed
motor must be plugged in)
Clear jam in feed tube
Dirty appliance
Cleanunitincludingthefirepot,
exhaust path, and venting system
Igniter has no power or is defective
Check igniter lead connections or
replace igniter
Exhaust probe not properly installed
Secure exhaust probe to exhaust
blowerhousing–keepingitswire
away from hot surfaces
Igniter chamber plugged with debris
Clean igniter chamber
6RedFlashes:ExhaustBlower
Alarm
Wire from exhaust blower or encoder
is disconnected or shorted
Make sure wire is not damaged /
melted and ends are fully connected
to the encoder and control board.
Defective exhaust blower
Replace exhaust blower
Defective encoder (on end of
exhaust blower)
Replace exhaust blower
8RedFlashes:ExhaustOver-Temp
FeedMotorLockedOn
Repair wire(s) and replace control
board
Non-approved fuel used
Onlyusewoodpelletfuel.Donot
enhance its performance with any
other combustible substance.
Convection blower dirty
Clean impellers