MT. VERNON E2
N. Restarting the Appliance
Restart Process
1. When the unit has run out of fuel and the “empty
hopper”errorcodeilluminates,addpelletfueltothe
hopper.
2. Dumptheashesandclinkersbuiltupinthefirepotby
pulling the ash dump removal handle out several times.
Make sure clinkers have dropped into the ash pan then
return the handle to fully closed position.
3. TurnthedialcontroltoOFFandandthenuptohigh2X
to prime.
4. After seeing pellets drop then turn to desired setting to
resettheappliancecontrolsystem.Theappliancewill
then being its startup sequence.
Restarting After a Power Failure
1. For an electrical disruption the appliance will start on
its own without need for priming - providing the control
system is asking for heat.
2. Theappliancewillalwaysgothroughanormalshut-
down sequence before restarting.
Remote Power Requirements
• Theremotereceiver power is maintained through appli-
ance power.
• Theremotethermostat uses four AAA batteries.
O. Clear Space
NOTICE: Clearancesmayonlybereducedbymeans
approvedbytheregulatoryauthorityhavingjurisdiction.
Mantel: Avoid placing candles and other heat-sensitive ob-
jects on mantel or hearth. Heat may damage these objects.
P. Trim Adjustment
Thesmalldiallocatedbelowthemaindialcontrolisused
toadjusttheamountofcombustionairforthefire.Youmay
needtoadjustthecombustionairtothefirefor:
• Elevation
• Venting/InstallationConfigurations
• Fuel Quality
Ifyourfireistoolarge,lazy,orproducingblacksoot,you
needMOREair.Toincreasetheamountofcombustion
air, rotate the dial clockwise one level at a time and allow
15 minutes for stabilization prior to making another adjust-
ment.Ifthefirecontinuestoappeartoorichturnthetrim
dial setting counterclockwise to the negative numbers to
decreasefuelflow.
Figure 12.1
Ifthefireistoosmalloroccasionallygoesoutwhenthere
are pellets in the hopper, the unit may have too much air.
Todecreasetheamountofcombustionair,rotatethetrim
dial towards zero one level at a time and allow 15 min utes
for stabilization prior to making another adjustment.
Q. Remote Thermostat
Learning Remote Thermostat to Receiver
1. With receiver and remote thermostat powered, set the
receiverto“REMOTE”andremotethermostatto“ON”.
2. Pushreceiver“LEARN”buttonmomentarily-anaudi-
ble tone should emit from the receiver.
3. Pushtheremotethermostat“MODE”buttonuntil“OFF”
shows on the screen - an audible sound should emit
from the receiver.
4. Tocheckwhetherthereceiveris“learned”push
“MODE”ontheremotethermostatseveraltimes-an
audible sound should be heard from the receiver.
5. If no sound is heard repeat the process.
Remote Thermostat: Instructions
1. Theremotethermostatactivatesaninternal“on-off”
switch in the receiver (located in the appli ance).
2. If the remote thermostat setting is higher than its local
surrounding temperature it will signal the receiver to
turnON;iftheusersettingisequalto-orlessthanthe
local surrounding temperature then the remote thermo-
statwillsignalthereceivertoturnOFF.
Remote Thermostat: Setting Clock
1. Push“TIMER”onthescreenofformorethantwosec-
onds.Thehourdigit(s)shouldbegintoflash.
2. PresstheUPorDOWNbuttonsuntilthedesiredhour
is displayed (notice the AM - PM).
3. After setting the desired hour, press and release
“TIMER”againandtheminutedigitswillbeginflashing.
4. PresstheUPorDOWNbuttonsuntilthedesiredmin-
utes are displayed.
5. Press“MODE”or“TIMER”buttonsagainformorethan
two seconds then release.
6. Theminutedigitswillstopflashing,theclockhasbeen
successfully set.
Remote Thermostat: Countdown Timer Function
1. Changethemodeto“ON”(or“THERMON”withtheset
pointhigherthantheroomtemperature),push“TIMER”
on the screen.
2. 0:15shouldappearonthescreen.
3. Pressing the up and down arrows will allow for increase
and decrease of the timer (15-minute increments up to
1-hour;30–minuteincrementsafter1-hour).
4. When the timer expires the remote should send an
“OFF”signaltotheappliance.
Figure 12.1
More Air
MoreAir&LessFuel