Quadra-Fire MTV-E2-CSB Installation Manual

Summary of MTV-E2-CSB

  • Page 1

    1 7080-131b march 14, 2014 mt. Vernon pellet stove e2 model(s): mtv-e2-csb mtv-e2-mbk mtv-e2-pft mtv-e2-pdb mtv-e2-pbk mtv-e2-pmh installation manual installation & appliance set-up installer: leave this manual with party responsible for use and operation. Owner: retain this manual for future refere...

  • Page 2

    2 7080-131b march 14, 2014 mt vernon e2 table of contents safety alert key: • danger!Indicatesahazardoussituationwhich,ifnotavoidedwillresultindeathorseriousinjury. • warning!Indicatesahazardoussituationwhich,ifnotavoidedcouldresultindeathorseriousinjury. • caution!Indicatesahazardoussituationwhich,...

  • Page 3

    March 14, 2014 7080-131b 3 mt vernon e2 thequadra-firemt.Vernone2pelletstovemeetstheu.S.Envi- ronmentalprotectionagency’s1990particulateemissionstandards. 1 important safety information note:hearth&hometechnologies,manufacturerof thisappliance,reservestherighttoalteritsproducts,their specificationsa...

  • Page 4: Install Guide

    4 7080-131b march 14, 2014 mt vernon e2 install guide 2 getting started marginal location: • below peak location not recommended: • not the highest point of the roof • wind loading possible multi-level roofs windward leeward recommended: outside air intake on windward side not recommended: outside a...

  • Page 5

    March 14, 2014 7080-131b 5 mt vernon e2 • installation and use of any damaged appliance. •modificationoftheappliance. • installationotherthanasinstructedbyhearth&home technologies. • installation and/or use of any component part not approvedbyhearth&hometechnologies. • operating appliance without fu...

  • Page 6

    6 7080-131b march 14, 2014 mt vernon e2 attention installer: follow this standard work checklist thisstandardworkchecklististobeusedbytheinstallerinconjunctionwith,notinsteadof,theinstructionscontainedinthisinstallationmanual. Customer: date installed: lot/address: location of fireplace: installer: ...

  • Page 7

    March 14, 2014 7080-131b 7 mt vernon e2 figure 7.4 - front view figure 7.1 - top view with top vent adapter and 3 to 6 in (76-152mm) adapter figure 7.5 - side view figure 7.2 - side view with top vent adapter and 3 to 6 in (76-152mm) offset adapter. 31-1/16 [788] 29-3/16 [741] q 5-13/16 [147] 2-9/16...

  • Page 8

    8 7080-131b march 14, 2014 mt vernon e2 straight back against wall inches millimeters a back wall to appliance 2 51 b side wall to appliance 6 152 corner installation inches millimeters c walls to appliance 2 51 vertical installation inches millimeters d back wall to flue pipe 3 76 e side wall to ap...

  • Page 9

    March 14, 2014 7080-131b 9 mt vernon e2 a c b d note: • illustrationsreflecttypicalinstallationsandarefor designpurposesonly. • i llustrations/diagramsarenotdrawntoscale. • actualinstallationmayvaryduetoindividualdesign preference. D. Alcove figure 9.1 *allminimumslistedaretoacombustiblesurface. Min...

  • Page 10

    10 7080-131b march 14, 2014 mt vernon e2 4 vent information a. Venting termination minimum requirements j or k x v m i h a v g b v v a b v f v c b b e l v d v electrical service v n v n v n n v inside corner fixed closed open open fixed closed v x g g termination cap air supply inlet gas meter restr...

  • Page 11

    March 14, 2014 7080-131b 11 mt vernon e2 b. Avoiding smoke and odors negative pressure, shut-down and electrical power failure to reduce the probability of back-drafting or burn-back in the pellet appliance during power failure or shut down con- ditions, it must be able to draft naturally without ex...

  • Page 12

    12 7080-131b march 14, 2014 mt vernon e2 c. Negative pressure negative pressure results from the imbalance of air avail- ablefortheappliancetooperateproperly.Itcanbestrongest inlowerlevelsofthehouse. Causesinclude: • exhaustfans(kitchen,bath,etc.) • rangehoods • combustionairrequirementsforfurnaces,...

  • Page 13

    March 14, 2014 7080-131b 13 mt vernon e2 f. Equivalent feet of pipe thetablebelowcanhelpyoucalculatetheequivalentfeet ofpipewhichisamethodusedtodeterminepelletventsize. Figure 13.1. 2 ft. 2 ft. 3 ft. 2 ft. Example of 3 elbow-rear vent termination calculation pellet venting component # of elbows feet...

  • Page 14

    14 7080-131b march 14, 2014 mt vernon e2 2 in [51mm] min 6 in [152mm] min 6 in [152mm] min non-combustible hearth pad wall thimble horizontal termination cap straight out figure 14.1 figure 14.2 wall thimble illustration shows venting going in both directions. Choose which one is best for your insta...

  • Page 15

    March 14, 2014 7080-131b 15 mt vernon e2 c. Through the wall & vertical - exterior firestop flashing rain cap 6 in [152mm] min non-combustible hearth pad 3 in [76mm] min clean-out cover 12 in. [305mm] min ceiling support 3 to 6 in [76 to 152mm] offset adapter 6 in. [152mm] class a chimney connector ...

  • Page 16

    16 7080-131b march 14, 2014 mt vernon e2 e. Masonry f. Alternate masonry concrete cap non-combustible hearth pad 6 in [152mm] min airtight clean-out door sheathing 1 in [25mm] clearnance 2 in [51mm] min to combustible material flashing fireclay flue liner with airspace 1 in [25mm] clearance with fir...

  • Page 17

    March 14, 2014 7080-131b 17 mt vernon e2 6 appliance set-up figure 17.3 - bolt fully extended figure 17.2 figure 17.1 a. Leg leveling system 1. Threadallenboltsthroughnutsuntilflush. Figure 17.1. The allenboltsandnutsareincludedinthecomponentpack inside the appliancefirebox. 2.Slideassemblednutsandb...

  • Page 18

    18 7080-131b march 14, 2014 mt vernon e2 3 in. To 6 in. Offset adapter silicone rear exhaust outlet 3 in. To 3 in. Top vent adapter clean-out cover drill hole, 1 on each side c. Top vent adapter installation 3 to 3 inch (76-76mm) top vent adapter 3 to 6 inch (76-152mm) top vent offset adapter instal...

  • Page 19

    March 14, 2014 7080-131b 19 mt vernon e2 caution logs are fragile. Use extreme care when handling or cleaning logs. Notice: duetotheabrasivenatureofapelletappliancefire,thelogs arenotcoveredunderwarranty.Anyplacementvariation otherthanshownherecancauseexcessiveheatandshall voidtheappliancewarranty. ...

  • Page 20

    20 7080-131b march 14, 2014 mt vernon e2 f. Remote thermostat installation 1. Whenmountingthethermostatonthewall,besureto followyourremotethermostat’sinstallationinstructions carefully. Note: the remote thermostat should be mounted on an inside wall and not in direct line with the ap- pliance convec...

  • Page 21

    March 14, 2014 7080-131b 21 mt vernon e2 7 mobile home installation you must use a quadra-fire outside air kit for installation in a mobile home. 1. Anoutsideairinletmustbeprovidedforthecombustion airandmustremainclearofleaves,debris,iceand/or snow.Itmustbeunrestrictedwhiletheapplianceisin usetoprev...

  • Page 22: Mt Vernon E2

    22 7080-131b march 14, 2014 mt vernon e2 8 accessory list service parts r mt vernon e2 beginning manufacturing date: dec 2013 ending manufacturing date: active important:thisisdatedinformation.Partsmustbeorderedfromadealerordistributor. Hearth and home technologies does not sell directly to consumer...

  • Page 23

    March 14, 2014 7080-131b 23 mt vernon e2.

  • Page 24

    24 7080-131b march 14, 2014 do not discard this manual caution • importantoperatingand maintenance instruc- tionsincluded. • leavethismanualwith partyresponsibleforuse andoperation. • read,understandand follow these instruc- tionsforsafeinstalla- tionandoperation. Do not discard contact information ...