18
7080-132J
January 8, 2016
MT. VERNON E2
Figure 18.1
Ash Dump Lever
Handle glass assembly with care.
When cleaning glass door:
• Avoid striking, scratching or slamming
glass.
CAUTION
• Do NOT clean glass when hot.
• Do NOT use abrasive cleaners.
• Use a hard water deposit glass cleaner on white fi lm.
Refer to maintenance instructions.
Handle glass doors with care.
• Inspect the gasket to ensure it is
undamaged.
• Do NOT strike, slam or scratch glass.
• Do NOT operate appliance with glass door
removed, cracked, broken or scratched.
WARNING
6. Cleaning the Hopper
• Frequency:
See chart on page 15
• By:
Homeowner
a. Be sure the appliance is allowed to cool.
b. After burning approximately 1 ton of fuel you will need to
clean the hopper to prevent sawdust and/or fi nes build-up.
c. A combination of sawdust/fi nes and pellets on the auger
reduces the amount of fuel supply to the fi repot.
d. This can result in nuisance shut downs and mis-starts
•. Empty the hopper of any remaining pellets.
•. Vacuum the hopper and feed tube.
7. Cleaning the Glass
• Frequency:
See chart on page 15
• By:
Homeowner
a. Be sure the appliance is allowed to cool.
b. Clean glass with a non-abrasive commercially available
cleaner. Wipe down with dry towel.
5. Ash Removal System Inspection & Cleaning
• Frequency:
Monthly or after burning 50 bags
• By:
Homeowner
a. Be sure the appliance is allowed to cool.
b. Open the front cast door and cycle the ash removal handle
- these should be inspected for functionality
c. Inspect for any degradation or deformation.
As the springs heat up and cool down they can lose
tension
If there is a gap showing above the fi repot bottom,
approximately 1/16 inch (1.59mm) or more, it means
the springs have lost their tension
Lost tension cannot keep the fl oor in the proper
position causing ignition problems and fuel falling
into the ash pan. If noted, call your dealer to replace
the springs.
8. Door Latch & Gasket Inspection
• Frequency:
See chart on page 15
• By:
Homeowner
The door latch is non-adjustable but the gasketing between
the glass and fi rebox should be inspected periodically to make
sure there is a good seal. If the gasket is frayed or damaged,
replace with a new one.
WARNING
Risk of fi re!
Do NOT store fuel:
• Closer than required clearances to combustibles
to appliance.
• Within space required for loading or ash removal