Document 81-81770-01 a01, june 2007 1 quantum scalar 50 tape drive removal and replacement instructions preparing for the procedure 3 required tools ...........................................................................................................3 unpacking the tape drive ....................
Quantum scalar 50 tape drive removal and replacement instructions document 81-81770-01 a01 june 2007 2 made in the usa. Quantum corporation provides this publication “as is” without warranty of any kind, either express or implied, including but not limited to the implied warranties of merchantabilit...
Quantum scalar 50 tape drive removal and replacement instructions document 81-81770-01 a01 june 2007 preparing for the procedure 3 preparing for the procedure 0 this document explains how to remove and replace a tape drive in an quantum scalar 50 library. Before you begin the removal and replacement...
Quantum scalar 50 tape drive removal and replacement instructions document 81-81770-01 a01 june 2007 4 turning off drive power 3 remove the foam from the wrapped tape drive. 4 remove the tape drive from the antistatic bag. Turning off drive power 0 there are two ways to turn of the tape drive power,...
Quantum scalar 50 tape drive removal and replacement instructions document 81-81770-01 a01 june 2007 turning off drive power 5 figure 2 drive operations screen 3 use the up and down arrows to select the tape drive to be replaced and press enter . 4 user the up and down arrows to select pwr off and p...
Quantum scalar 50 tape drive removal and replacement instructions document 81-81770-01 a01 june 2007 6 turning off drive power figure 3 overview page 4 click the operations tab from the top of the overview page. The operations page displays . 5 to access the drives page, from the operations page, cl...
Quantum scalar 50 tape drive removal and replacement instructions document 81-81770-01 a01 june 2007 removing the faulty tape drive canister 7 the tape drive power is turns off. Removing the faulty tape drive canister 0 to remove the faulty tape drive canister: 1 use a flat blade screwdriver to loos...
Quantum scalar 50 tape drive removal and replacement instructions document 81-81770-01 a01 june 2007 8 installing the new tape drive canister 2 pull the scsi sub-plate from the drive (see figure 7 ). 3 use a flat blade screwdriver to loosen the tape drive thumbscrew (see figure 5 ). 4 pull the tape ...
Quantum scalar 50 tape drive removal and replacement instructions document 81-81770-01 a01 june 2007 replacing the scsi sub-plate 9 2 slowly insert the new tape drive into the library until the connectors are seated. 3 tighten the tape drive thumbscrew using a flat-blade screwdriver. 4 for scsi tape...
Quantum scalar 50 tape drive removal and replacement instructions document 81-81770-01 a01 june 2007 10 repackaging the faulty tape drive canister a use a flat-blade screwdriver to loosen the two thumbscrews on the scsi sub-plate (see figure 5 ). B pull the scsi sub-plate from the drive. 5 install t...
Quantum scalar 50 tape drive removal and replacement instructions document 81-81770-01 a01 june 2007 troubleshooting 11 figure 7 wrapped tape drive 5 place the wrapped tape drive in the shipping carton. 6 secure the carton for shipment. The tape drive is ready to be returned to the vendor. Troublesh...
Quantum scalar 50 tape drive removal and replacement instructions document 81-81770-01 a01 june 2007 12 troubleshooting swapping a tape drive 0 in the event that you have lost scsi or fibre channel communication with a tape drive, it is recommended that you swap the failed tape drive canister with a...