Radionics D8024 Operator's Manual

Other manuals for D8024: Networking Manual
Manual is about: Analog Fire Alarm Control Panels

Summary of D8024

  • Page 1

    35394b 11/98 © 1998 radionics, inc. D8024 analog fire alarm control panel operator’s guide ® radionics power system trouble trouble silenced alarm silenced point bypassed alarm system reset trouble silenced silence alarm alarm manual keyp ad enable disable keypad ® radionics d8024.

  • Page 2: Table of Contents

    Table of contents d8024 operator’s guide 35394b 11/98 page 1 © 1998 radionics, inc. All rights reserved. 1.0 notice .............................................................................................................................................................................3 2.0 warni...

  • Page 3: Table of Figures

    Table of figures d8024 operator’s guide © 1998 radionics, inc. All rights reserved. Page 2 35394b 11/98 figure 1: d8024 fire alarm control panel ............................................................................................................................4 figure 2: d8024 front panel d...

  • Page 4: Operator’S Manual

    D8024 analog fire alarm control panel d8024 operator’s guide 35394b 11/98 page 3 © 1998 radionics, inc. All rights reserved. Operator’s manual 1.0 notice • the material and instructions covered in this manual have been carefully checked for accuracy and are presumed to be reliable. However, the manu...

  • Page 5

    D8024 operator’s guide © 1998 radionics, inc. All rights reserved. Page 4 35394b 11/98 5.0 control levels 5.1 level distinction • the d8024 has three available control levels. At all three levels the led display indicates condition, the zone/area leds indicate location, and detailed alarm/trouble in...

  • Page 6

    D8024 operator’s guide 35394b 11/98 page 5 © 1998 radionics, inc. All rights reserved. Key label function shift shows user options on alphanumeric display. Used in programming to allow letters n to z. 0,1,2,3,4,5,6,7,8 9 press to silence all notification appliances. Press again to activate all notif...

  • Page 7

    D8024 operator’s guide © 1998 radionics, inc. All rights reserved. Page 6 35394b 11/98 figure 3: led display • if the 120v ac power source is interrupted, the ac power led will flash, the panel buzzer will sound, and the system trouble and the earth fault leds will light. The illumination will go ou...

  • Page 8

    D8024 operator’s guide 35394b 11/98 page 7 © 1998 radionics, inc. All rights reserved. • press key 3 on the alphanumeric key row. The display returns to main menu. The control keys are now enabled for the amount of time programmed into the panel. At the end of the programmed time period the panel wi...

  • Page 9

    D8024 operator’s guide © 1998 radionics, inc. All rights reserved. Page 8 35394b 11/98 figure 8: level two controls alarm signal response • press the alarm silence key to turn off notification appliances external to the panel. Thealarm silenced led will light. Pressing the alarm silence key again tu...

  • Page 10

    D8024 operator’s guide 35394b 11/98 page 9 © 1998 radionics, inc. All rights reserved. Leds test • select the first option,1) leds, by pressing the1 key. The panel will flash all leds on the led display and step through all the alarm and trouble leds in the zone/area display. On completion of the te...

  • Page 11

    D8024 operator’s guide © 1998 radionics, inc. All rights reserved. Page 10 35394b 11/98 • sounding the panel buzzer • lighting the led at the device in alarm. • after a few seconds, the panel will automatically reset and turn off the device led. The panel allows up to one minute for smoke devices to...

  • Page 12

    D8024 operator’s guide 35394b 11/98 page 11 © 1998 radionics, inc. All rights reserved. Manual call points (alarm boxes) within the zone are not disabled. • when a device is disabled, the amber point bypassed led on the led display lights. The amber trouble led in the corresponding zone of the zone/...

  • Page 13

    D8024 operator’s guide © 1998 radionics, inc. All rights reserved. Page 12 35394b 11/98 the disabled output must be enabled before the system can be reset. • to enable the outputs, press the no key to revert to the main menu. Enter the enable menu by selecting option four, 4) enable. Select option f...

  • Page 14

    © 1998 radionics, inc. All rights reserved. ® the radionics logo is a registered trademark of radionics, inc. 1800 abbott street, salinas, ca 93901, usa comments? Suggestions? E-mail: techwriters@radionicsinc.Com view devices • option one on the view menu allows the operator to view the current stat...