Codecs—H.261, H.263, H.263+, H.264, H.264 SVC
–
Live video resolutions—QCIF up to 1080p
–
Presentation video resolution—VGA, SVGA, SXGA, 720p, 1080p, WUXGA
–
Video bandwidth—up to 12Mbps for 1080p resolutions and up to 6Mbps for 720p or lower
•
Call capacity:
See
Table 1-1 on page 6
for the list of MCU call capacity licenses.
–
If you have the Increased Capacity license option installed, the MCU should be
pre-configured to either X2 or X4 capacity:
If you enable X2 capacity, resolutions of 480p and lower use only half a port, while higher
resolutions use 1 port (except for 1080p, which uses 2 ports).
If you enable X4 capacity, resolutions of 352p use 1/4 a port, and higher resolutions use
1 port (except for 1080p, which uses 2 ports).
For more information, contact Customer Support.
–
If you do not have the Increased Capacity license option, resolutions of 720p and lower
use 1 port, and resolutions of 1080p use 2 ports.
Note:
By default, all conferences are in Continuous Presence mode, which supports different
layouts and endpoints with various resolutions.
To increase your call capacity, you can configure your conference for video switching
(see the Configuring the Conference Mode section in the Administrator Guide of SCOPIA
Elite MCU).
Table 1-1
Call Capacity
Call Resolution
Ports per Call
SCOPIA Elite MCU
5105 (1U) Capacity
SCOPIA Elite
MCU 5110 (1U)
Capacity
SCOPIA Elite
MCU 5115 (1U)
Capacity
Basic Product Capacity
HD (1080p) continuous presence
2 ports per call
3 ports
5 ports
7 ports
HD (720p) continuous presence
1 port per call
5 ports
10 ports
15 ports
HD video switching
1/4 - Four times
the number of calls
20 ports
40 ports
60 ports
Increased Capacity License option
ED (480p) continuous presence (if X2
capacity is enabled)
1/2 - Double the
number of calls
10 ports
20 ports
30 ports
ED (352p) continuous presence (if X4
capacity is enabled)
1/4 - Four times
the number of calls
20 ports
40 ports