RADVision Scopia Elite 5100 Series Installation Manual - page 56
Performing the MCU Initial Configuration | 52
RADVISION | Installation Guide for SCOPIA Elite 5100 Series MCU Version 7.7
Verifying the MCU Installation
After you installed the device and performed its initial configuration, you need to verify that it is
installed and configured correctly.
Procedure
Step 1
On the front panel, verify that the power alarm LED is lit green lower down on the unit.
Figure 5-21
Locating the front panel LEDs
Step 2
On the front panel, verify that the status LED is lit green.
Step 3
Check the network connection by verifying that the Ethernet activity LED is lit green.
Note:
The left LED on the Ethernet connector lights green if the connection speed reaches 1000
Mbps, and lights orange if the connection speed reaches 100 Mbps.
Step 4
If one of the LEDs does not light as described in the previous steps, the device is not functioning
properly. See the MCU Troubleshooting Guide to resolve the issue.
Step 5
Verify the device is ready for use by creating a conference:
a.
From an endpoint dial the MCU IP address.
You access the MCU auto attendant service which plays the video and audio prompts.
b.
Press 0 to create a new conference.
c.
At a prompt, enter the meeting ID and press #.
The MCU creates the conference and you see the Conference window.
d.
Exit the conference by disconnecting the call.