RAINSMART RainSmart User Manual - page 18
B2
Verifying Float
Sensor
If possible, retrieve the float sensor from the tank. Both of the conditions should
work otherwise there is a failure
o
Let the float sensor dangle (float is pointing down with lead coming out
of the top.
The
RainSmart
TM
should indicate “Mains Water”.
o
Raise the float level so the float is pointing up with the lead hanging out
of the bottom.
The
RainSmart
TM
should indicate “Rain Water”
If either of the above tests fail, there is a problem with the float sensor.
G
en
er
a
l
T
es
ts
C
Verify Pump
manual/auto mode
Ensure that the indicator on the
RainSmart
TM
unit changes from “Pump Auto” to “Pump
Manual”.
If not, return the
RainSmart
TM
unit for service as a failure has occurred
D
Verify Mains Valve
operation
Press the test button
Mains valve operates. There is a visual indicator on top of the mains valve that
indicates the direction of the ball valve. When pressing the test button this
should rotate and then 15 seconds later rotate again. If mains valve does not
operate, check the connection of the mains valve to the
RainSmart
TM
. If this is
ok, then either the mains valve or
RainSmart
TM
may be faulty.
E
Verify Pump Outlet
Unplug the Pressure Pump from
RainSmart
TM
and plug-in a portable appliance instead
Set the mode to pump manual mode
o
The appliance should turn on
If the appliance does not operate, there is a problem with the
RainSmart
TM
control unit
If the appliance turns on, the pressure Pump has failed!