TERMINAL STRIP CONNECTIONS
TERMINAL #1 – COMMON
Low voltage common.
TERMINAL #2 – SAFETY
Normally Closed. Becomes active with an open con-
tact to common. If the gate is closed, it will have no
effect. If the gate is opening, it will have no effect. If the
gate is opened, it will hold the gate open. If the gate is
closing it will stop and automatically reopen the gate.
Remove the factory jumper when using.
TERMINAL #3 – COMMON
Low voltage common.
TERMINAL #4 – EXIT
Normally open. Becomes active with a closed contact
tocommon.Usedwithloopdetectors,exitwands,fire
boxes, keypads, etc… Opens the gate. If the gate is
closed, it will open the gate. If the gate is opening it
will have no effect. If the gate is opened, it will hold the
gate open. If the gate is closing, it will stop and reopen
the gate.
TERMINAL #5 – PhANTOM
This terminal is currently not active.
TERMINAL #6 – COMMON
Low voltage common.
TERMINAL #7 – RADIO
Normally open. Becomes active with a closed contact
to common. Used with RF receivers, keypads, push-
buttons, etc… Opens and closes the gate. Operation
depends on the position of Dip Switch #2 (Radio Cycle)
Dip switch #2 – OFF: If the gate is closed it will
open all the way. If the gate is open it will close all
the way. If the gate is traveling it will have no effect.
Dip switch #2 – ON: Cycle mode. The gate will open
and close to it’s limits but if a command it triggered
while traveling the gate will; stop on the first
command and reverse on the second command.
TERMINAL #8 – STOP
Normally Closed. Becomes active with an open con-
tact to common. Used with back plane photo eyes,
edge sensors, etc… If the gate is closed it will hold the
gate closed. If the gate is opening it will stop the gate
and hold it. To reactivate the motion a second com-
mand must be input and then the gate will reverse it’s
direction. If the gate is open it will hold the gate open.
If the gate is closing it will stop the gate and hold it. To
reactive the motion a second command must be input
and then the gate will reverse it’s direction.
TERMINAL #9 – COMMON
Low voltage common.
TERMINAL #10 – PhO 2
Normally Closed. Becomes active with an open con-
tact to common. Used with photo eyes, loop detectors,
safety edges, etc… Operation depends upon the posi-
tion of the Dip Switch #4 (Pho 2/ Edge)
Dip switch #4 – ON: If the gate is closed it holds the
gate closed. If the gate is opening it stops the gate
until the sensor is cleared and then it automatically
continues to open the gate. If the gate is open it
holds the gate open. If the gate is closing it stops
the gate and until the sensor is cleared and then
reverses the motion to reopen the gate automatically.
Dip switch #4 – OFF: If the gate is closed it holds
the gate closed. If the gate is opening it stops the
gate and reverses it’s motion for 2 seconds.
Another command must be received for the gate to
continue. If the gate is open it holds the gate open.
If the gate is closing it has no effect.
TERMINAL #11 – COMMON
Low voltage common.
TERMINAL #12 – 24 vDC
24 volt DC output for photocells, keypads, etc…
TERMINAL #13 – MAG –
Negative terminal for magnetic lock.
TERMINAL #14 – MAG +
Positive terminal for magnetic lock.
TERMINAL #15 & #16 – MOT 1
Input for motor wire coming from operator. If gate clos-
es instead of opening, reverse polarity by switching the
motor 1 wires.
TERMINAL #17 & #18 – MOT 2
Inputforsecondoperatorinamaster/slaveconfigura-
tion. If gate closes instead of opening, reverse polarity
by switching the motor 2 wires.
TERMINAL #19 – 120 vAC
120 Volt AC output terminal via switch. DO NOT wire
AC input power directly to this terminal.
TERMINAL #20 – NEUTRAL
Neutral output terminal via switch. DO NOT wire AC