DIP SWITCH
DIP SWITCh CONFIGURATION
Dip Switch 1 – MODE
ON The control unit is in slow mode. This setting is suitable
for all gates.
OFF
(used on gates under 6 ft) The unit is in fast mode. Make
sure that the gate does not strike too hard against the
mechanical stops or the operator could be damaged. If
so turn the switch ‘on’.
Dip Switch 5 – LOCK
ON Use this setting when operating a magnetic lock with
the operator.
OFF Use this setting when using an electric lock with the
operator.
Dip Switch 2 – RADIO CYCLE
ON
The operator is in cycle mode. It will start the gate mov-
ing on the first command, stop the gate on the second
command, and start the motion in the opposite direc-
tion on the next command.
OFF
The unit will open or close the gate depending on the
limits. The unit will not stop if a command is received
while the gate is moving. If closing the gate opens.
Dip Switch 6 – KICK BACK
ON
Kickback enabled. Used with the Modus operator. The
control board supplies a surge of reverse power to the
operator to release tension on the emergency release
mechanism. No function currently.
OFF The kickback feature is disabled. Keep this dipswitch
off when using the jet operator.
Dip Switch 3 – TIMER
ON
The automatic closing timer is activated. The gate will
automatically close according to the amount of time set
by the timer trimmer.
OFF The automatic closing timer is inactive. The operator
must receive a command to close the gate.
Dip Switch 7 – ONE PASS
ON
Rapid re-closing or “anti-tailgating” feature is enabled.
When this feature is active the gate will begin to re-
close as soon as the photocell or loop has been oc-
cupied and cleared. If the gate is opening it will reverse
direction and close without fully opening.
OFF The rapid re-closing feature is disabled.
Dip Switch 4 – PhO2/ EDGE
ON
(PhOTO EYE) Safety devices attached to terminal #10
(PHO2) will cause the operator to do as follows: If the
gate is open or closed it will not move until the sensor is
cleared. If the gate is opening it stops the gate until the
sensor is cleared and then automatically continues to
open the gate. If the gate is closing it stops the gate un-
til the sensor is cleared and then automatically opens
the gate.
OFF
(EDGE) If the gate is open or closed it will not move un-
til the sensor is cleared. If the gate is closing the safety
sensor has no effect. If the gate is opening the gate will
stop and reverse direction for 2 seconds. Another com-
mand must be received for the gate to continue.
Dip Switch 8 – PARTIAL
ON
Keep this switch ON for normal operation. The start
channel is memorized during programming of the radio
transmitter.
OFF
(this is used on very long gates when to open limits
are desired) In this mode a partial opening channel is
memorized during the programming of the radio trans-
mitter. WARNING: THIS IS A VEHICULAR GATE OP-
ERATOR. PEDESTRIANS SHOULD ALWAYS USE A
SEPARATE ACCESS DOOR.
Figure 14
DIP SWITCh
8–PARTIAL
7–ONE-PASS
6–KICK-BACK
5–LOCK
4–PHO 2/ EDGE
3–TIMER
2–RADIO CYCLE
1–MODE