Rasmussen CXF12 Installation Instructions Manual
CXF-705
Custom Embers Pan Burner
12028 E. Philadelphia St. Whittier , CA 90601 U.S.A.
(562) 696-8718 FAX (562) 698-3510
gaslogs@rasmussen.biz www.rasmussen.biz
GENERAL INSTALLATION INSTRUCTIONS
ASSEMBLY, INSTALLATION, AND OPERATION INSTRUCTIONS FOR RASMUSSEN
VENTED CUSTOM EMBERS PAN BURNER MODELS:
CXF for use with Natural Gas; CXFA for use with Propane (LP) Gas
IMPORTANT
READ THESE INSTRUCTIONS CAREFULLY BEFORE
STARTING INSTALLATION OF LOG SET.
WARNING:
Improper installation,
alteration, service or maintenance can cause
injury or property damage. Read these
instructions thoroughly before installation.
For assistance or additional information, consult
your gas log dealer, qualified installer, service
agency or gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS
•
Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbors phone. Follow the gas suppliers
instructions.
• If you cannot reach your gas supplier, call the
fire department.
IMPORTANT INFORMATION
THIS GAS LOG SET MUST BE INSTALLED IN A FULLY VENTED SOLID-FUEL BURNING
FIREPLACE WITH A WORKING FLUE CONSTRUCTED OF NON COMBUSTIBLE MATERIAL.
The minimum permanent free opening of the fireplace chimney or chimney damper must be at least the minimum
Chimney Area shown below, based on a minimum chimney height of at least 8 feet. The area of the flue must not be less
than 1/10 the area of the fireplace opening. The flue must exhaust all products of combustion.
The chimney damper must be fixed in a manner to maintain permanent free opening as outlined above at all times. To
accomplish this, install the damper clamp (provided) on the edge of the damper blade to prevent its closing, drill a hole or
holes in the damper, or remove damper completely.
The minimum size of the fireplace in which the log set is to be installed must be as follows:
MINIMUM FIREPLACE SIZE IN INCHES
Model/Set Size
HEIGHT
DEPTH
REAR WIDTH
FRONT WIDTH
GAS PIPING
CHIMNEY AREA
CXF12 - 12 INCH
CXF15 - 15 INCH
CXF18 - 18 INCH
CXF21 - 21 INCH
CXF24 - 24 INCH
CXF30 - 30 INCH
CXF36 - 36 INCH
16
16
16
16
16
16
18
12
12
14
14
14
14
16
12
15
18
.
21
24
30
36
16
20
24
27
32
38
44
½” i.d.
½” i.d.
½” i.d.
½” i.d.
½” i.d
½” i.d
½” i.d
6 INCH DIAMETER
7 INCH DIAMETER
7 INCH DIAMETER
8 INCH DIAMETER
8 INCH DIAMETER
9 INCH DIAMETER
10 INCH DIAMETER
.
Glass doors must be wide open when burner is lighted
to allow air for safe combustion, venting and cooling of valves.