Rasmussen CXF12 Installation Instructions Manual - •
4
Standard Match Lighted
• (For use only with Natural Gas Models CXF)
WARNING: A SAFETY PILOT CONTROL
MUST BE INSTALLED ON ALL UNITS
DESIGNED OR CONVERTED TO BURN
PROPANE/LP GAS
1. Apply pipe compound to threaded end of 3/8"
FLARED BRASS ELBOW (A). Do not apply pipe
compound to flared end. Thread into BURNER
PAN INLET (B) and wrench tighten. See Figure
2
A
B
Figure 2
Refer to assembly and installation instructions that come with kits when
installing accessory safety pilot lighting kits.
•
SPK3-CS, RPK3-CS, RPK-F10-CS, RMC1-CS (For use with Natural Gas Models CXF)
• SPK3-CA, RPK3-CA, RPK-F10-CA, RMC1-CA (For use with Propane Gas Models CXFA)
STEP TWO: Burner Pan Positioning.
REAR WALL
TOP VIEW
1. Place BURNER
PAN inside firebox as
far to the rear as
possible. Then center
BURNER PAN left to
right.
See Figures 3 and 4.
SIDE VIEW
Figure 3
Figure 4
STEP THREE: Gas Supply Connection
C
A
B
D
FIREPLACE GAS
SUPPLY VALVE
TYPICAL INSTALLATION
CXF
Burner
Figure 5
ENSURE THAT GAS SUPPLY
TO FIREPLACE IS TURNED OFF
1. Apply pipe compound to threaded end of GAS SUPPLY
PIPE (A). Thread 1/2" FIP x 3/8" FLARE ELBOW (B) onto GAS
SUPPLY PIPE (A) and wrench tighten. See Figure 12.
2. With BURNER PAN inside firebox, thread (without pipe
compound) one end of the ALUMINUM CONNECTOR TUBE
(C) to the 1/2" FIP x 3/8" FLARE ELBOW (B) and wrench
tighten.
3. Carefully bending ALUMINUM CONNECTOR TUBE (C),
align and connect, without pipe compound, to the FLARED
BURNER INPUT FITTING (D). Wrench tighten. Figure 5
NOTE: If bent into too small of a radius the
ALUMINUM CONNECTOR TUBE (C) may kink or break,
causing a gas leak.
4. Turn gas supply to fireplace on.
5. Test all connections for leaks with soapy water solution. If
solution bubbles, turn off gas supply, re-tighten fitting and
recheck.