Rasmussen CXF12 Installation Instructions Manual - Warning:
2
THIS BURNER IS FOR USE IN FULLY FUNCTIONING WOOD BURNING
FIREPLACE WITH THE DAMPER WIDE OPEN.
THE FLUE MUST VENT ALL PRODUCTS OF COMBUSTION.
.
IMPORTANT INFORMATION (continued)
A fireplace screen must be in place when the log set is in
operation and, unless other provisions for combustion air
are provided, the screen shall have opening(s) for
introduction of combustion air.
The minimum inlet gas supply pressure for the purpose of
input adjustment shall be 6 inches of water column on
natural gas and 11 inches of water column on propane
gas.
The maximum inlet gas supply pressure shall be 7 inches
of water column on natural gas and 14 inches of water
column on propane gas.
The installation and the provision for combustion and
ventilation air must conform with the NATIONAL
FUEL GAS CODE ANSI Z223.1 latest edition.
The gas log set and its individual shutoff valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of 1/2 psig (3.5 kPa). The gas log set must be
isolated from the gas supply piping system by closing its
individual manual shutoff valve during any pressure testing
of the gas supply piping system at test pressures equal to
or less than 1/2 psig (3.5 kPa).
The area around the gas log set must be clear and free
from combustible materials, gasoline and any other
flammable vapors and liquids.
Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
WARNING: A SAFETY PILOT MUST BE INSTALLED ON ALL UNITS DESIGNED OR CONVERTED TO
BURN PROPANE/LP GAS
.
When used with LP (Propane) Gas, ensure that the Burner Pan is filled with the
BLACK VOLCANIC ASH. White Sand is ONLY for use with Natural Gas.
WARNING: CARBON MONOXIDE POISONING MAY LEAD TO DEATH
When used without fresh air, gas log set may give off carbon monoxide, an odorless, colorless, poisonous
gas. Some people - pregnant women, persons with heart or lung disease, anemia, or under the influence of
alcohol and persons at high altitudes are more affected by carbon monoxide than others.
Early signs of carbon monoxide poisoning resemble the flu: Headache, dizziness, and/or nausea. If you have
these signs, the gas log may not be installed or working properly, or the chimney flue may be blocked.
GET FRESH AIR AT ONCE! Have gas log set and chimney flue serviced before using again.
.
DAMPER MUST BE WIDE OPEN WHILE BURNING
OPEN A WINDOW AN INCH OR TWO FOR
FRESH AIR WHEN USING YOUR GAS LOG
SOLID FUELS SHALL NOT BE BURNED IN A FIREPLACE
WHERE A DECORATIVE APPLIANCE IS INSTALLED.
WARNING:
If
not installed, operated and maintained in accordance with these
instructions, this product could expose you to substances in fuel or from fuel
combustion which are known to the State of California to cause cancer, birth defects
or other reproductive harm.