Rasmussen CXF12 Installation Instructions Manual - Magic Placement.
5
WARNING: DO NOT FLAME TEST FOR LEAKS.
.
STEP FOUR: White Sand, Black Volcanic Ash and Ember
Magic Placement.
1. Completely fill BURNER PAN, including
underneath the BAFFLE PLATE, with the
appropriate PAN MEDIUM. The WHITE SAND is
for use with Natural Gas, the BLACK VOLCANIC
ASH is for use with Propane/LP Gas. Use the
ENTIRE CONTENTS of the bag provided with the
burner.
Be sure to completely cover BURNER TUBES (main
and ember boosters). See Figure 13.
2. Sprinkle a light covering of "EMBER MAGIC"
over the PAN MEDIUM. Pull apart "EMBER MAGIC"
fiber material to enhance the glowing ember effect.
EMBER MAGIC
BAFFLE
BURNER PAN MEDIUM
BURNER TUBE
Figure 6
STEP FIVE: Log Placement.
SIDE VIEW FRONT VIEW TOP VIEW
(1) LOG SET. Place large LOGS on filled BURNER PAN. Allow 2” to 3” space between front and rear logs. Lay smaller logs on
bottom in cross position. CAUTION: Crowded logs will cause poor combustion and result in excessive soot formation.
(2) Pine Cones, FireBalls, FireShapes and FireStones: Spread EMBER MAGIC across PAN. Place large Shapes to form a base,
then fill in gaps with smaller Shapes.
STEP SIX: Lighting Instructions and Operation.
IMPORTANT: CHIMNEY DAMPER MUST BE WIDE OPEN
MANUAL MATCH LIGHTING.
• Standard Match Lit Set
(Applies only to Natural Gas Models CXF)
1. Place lighted match on embers near inlet end of burner. DO NOT HOLD MATCH IN HAND! Move away from front of fireplace.
2. Slowly open FIREPLACE GAS SUPPLY VALVE and wait for burner to light. (See FIGURE 7)
3. Adjust FIREPLACE GAS SUPPLY VALVE for desired flame height.
4. SHUTDOWN: Close FIREPLACE GAS SUPPLY VALVE completely
.
Refer to the lighting and operation instructions that come with kits when using
an accessory safety pilot lighting kits.
•
SPK3-CS, RPK3-CS, RPK-F10-CS, RMC1-CS (For use with Natural Gas Models CXF)
• SPK3-CA, RPK3-CA, RPK-F10-CA, RMC1-CA (For use with Propane Gas Models CXFA)