Raymarine ST60 Tridata Owner's Handbook Manual - Calibration On/off
32
ST60 Compass Instrument Owner’s Handbook
Calibration on/off
Controls access to the User calibration. Access can be either enabled ( UC1 ) or
disabled ( UC0 ), as required.
Use the
and
>
keys to set the value you want.
Note:
If the access to User calibration is disabled, then only the software version screen
will be available in Intermediate calibration; the instrument status screen will not be dis-
played.
Pointer response
The pointer response value determines how the analog pointer responds to
changes in data inputs. The higher the value, the more sensitive the pointer to
data changes. The range is from P1 to P15.
Use the keys to set the value you want.
Heading display response
The heading display response value determines how the digital display responds
to changes in data inputs. The higher the value, the more sensitive the display to
data changes. The range is from d1 to d15.
Use the
and
>
keys to set the value you want.
Boat show mode
CAUTION:
DO NOT enable this mode. It must be used for demonstration
purposes only.
Ensure that Boat Show Mode is set to bS0 (disabled). If necessary, use either the
key or the
>
key to achieve this.
Factory defaults
You can use this screen to reset the operating parameters to the factory default
values. Use the
and
>
keys to make the required selection.
Note that the selection you make at this screen will be applied when you exit the
screen, so be sure you make the correct selection.
If you want to apply the factory defaults, ensure the display shows F1 , but
if you
want to retain the current values,
ensure that the display shows
F0
.