SAFERA PCU3 Installation Manual - page 10
19
18
Adjust the alarm limit according to the reference table above. The default alarm limit
is 6.
First, go to the adjustment mode:
2
Check the closest
recommended alarm
limit from the refe-
rence table on the right.
The range is 1-12:
1 = reacts fastest
12 = reacts slowest
Then, adjust the alarm limit:
Lower the alarm limit
(-1): press the lock
button
❶.
Raise the alarm limit
(+1): press the OK-
button
❷.
= vakioasetus
1
Press the adjustment mode
button
❼: indicator light
panels
❽ lit white.
12
11
10
9
8
7
6
5
4
3
2
1
INSTALLATION - STEP 5/6
Adjust the alarm limit
When you adjust the
alarm limit, the new
alarm limit is indica-
ted as shown in the table on
the right.
3
ѥ WARNING
Do not set the alarm limit higher than 9
during the installation.
If the alarm limit is set too high, the app-
liance may fail to detect a hazardous situ-
ation in time.
ѧ HINT
You may check the alarm
limit by pressing the ad-
justment mode button
❼
twice.
Location of the Cooker
Installation
Height
Alarm Limit
(1-12)
In a corner
75 cm
6*
65 cm
7
55 cm
8
45 cm
9
Next to a wall
75 cm
5
65 cm
6*
55 cm
7
45 cm
8
In an island
75 cm
4
65 cm
5
55 cm
6*
45 cm
7
* Default
Color of the indicator
light panels
❽
Number of
beeps
Alarm Limit
Red
••• •••
12
••• ••
11
••• •
10
•••
9
••
8
•
7
Blue
••• •••
6 (default)
••• ••
5
••• •
4
•••
3
••
2
•
1