SAFERA PCU3 Installation Manual - page 7
13
12
ѥ WARNING
Make sure that there is no power supply to
the cooker and the oven by removing their
fuses. Also ensure that the cooker is swit-
ched off.
OUT-wires are always energized when
the power control unit is connected to the
electrical network. If a wire is loose, it must
be properly covered.
Do not install the Power Control Unit to ex-
cessive heat: Operational ambient tempera-
ture is +5 … +40°C.
⚐ ATTENTION
Install the power control unit
Ⓒ so that it
is not exposed to moisture. Check that all
cables can move freely.
IN
3 x 4 mm
2
OUT
3 x 4 mm
2
180 mm
60 mm
130 mm
Optional water
sensor connection.
See chapter 4.
Remove the fuses to the cooker and oven.
Mount the power control unit
Ⓒ on the wall behind the cooker or into the cabinet
next to the cooker.
Couple the protective earth first (PE).
Couple the other wires.
Don’t reconnect the power to the cooker yet.
Installation
PCU5.1-U - INSTALLATION
Fixed 1-phase connection.
OFF
OUT
IN
PE
L/N
L
PE
N
L
230V MAX. 25A
MICRO DISCONNECTION
ѧ HINT
If you are replacing a cooker, press the ad-
justment mode button
❼ for five seconds
until you hear a signal. Continue the
installation according to step 3/6.
3
4
5
2
1