Salicru UPS SLC TWIN PRO series User Manual

Other manuals for UPS SLC TWIN PRO series: User Manual

Summary of UPS SLC TWIN PRO series

  • Page 1

    Uninterruptible power supply (ups) + lighting flow dimmer stabilizers (iluest) + switch mode power supply + static inverters + photovoltaic inverters + voltage stabilizers and power line conditioners ups slc twin pro series 0.7 to 3 kva user’s manual uninterruptible power supply.

  • Page 3: General Index

    3 salicru general index 1. Introduction. 1.1. Acknowledgement letter. 1.2. Using this manual. 1.2.1. Conventions and used symbols. 1.2.2. For more information and/or help. 1.2.3. Safety instructions. 1.2.3.1. General safety warnings. 1.2.3.2. To keep in mind. 1.2.3.3. Safety warning regarding batter...

  • Page 4: 1.  Introduction.

    4 salicru 1. Introduction. 1.1. Acknowledgement letter. We would like to thank you in advance for the trust you have placed in us by purchasing this product. Read this instruction manual carefully before starting up the equipment and keep it for any possible future consult that can arise. We remain ...

  • Page 5

    5 salicru the installation or commissioning tasks, because there could be a risk on your safety or on the other/s persons, being able to make serious injuries even the death, also it can cause damages to the equipment and/or to the loads and installation. • the local electrical regulations and the d...

  • Page 6

    6 open, so the button must be switched to close the circuit and the voltage to the loads is broken. To establish the power supply to the loads again, the epo button must be deacti- vated. Epo doesn’t affect to the power supply of the equipment, it only breaks the power supply to the loads as a safet...

  • Page 7

    7 salicru 1.2.3.3. Safety warning regarding batteries. • the manipulation and connection of the batteries shall be done and supervised by personnel with battery knowledge only. Before doing any action, disconnect the batteries. Check that no current is present and there is not dangerous voltage in t...

  • Page 8: 2.  Quality And Standard

    8 2. Quality and standard guarantee. 2.1. Declaration of the management. Our target is the client’s satisfaction, therefore this management has decided to establish a quality and environmental policy, by means of installation a quality and environmental management system that becomes us capable to c...

  • Page 9: 3.  Presentation.

    9 salicru 3. Presentation. 3.1. Views. 3.1.1. Views of the equipment. Figures 1 to 6 show the illustrations of the equipment according to the case format and depending on the power of the model. Nevertheless and due to the constant evolution of the product, some discrepancies or small contradictions...

  • Page 10

    10 protection cover for smart slot output sockets input socket input breaker protection fan usb transient protection (*) epo extended autonomy connector protection cover for smart slot output sockets input socket input breaker protection fan usb transient protection (*) epo (*) transient protection ...

  • Page 11

    11 salicru model from 3 kva (standard) model from 3 kva (b1) (*) transient protection (fax, modem,...) output sockets input socket input breaker protection fans usb transient protection (*) epo output terminals protection cover for smart slot extended autonomy connector output sockets input terminal...

  • Page 12

    12 battery module for models 0.7 and 1 kva battery module for models 1.5 from 3 kva fig. 5. Front view from battery module. Battery module for models 0.7 and 1 kva battery module for models 1.5 from 3 kva connector for connection to another module connector for ups (extended autonomy) earthing screw...

  • Page 13

    13 salicru 3.2. Definition of the product. 3.2.1. Nomenclature. Slc-2000-twin pro (b1) wco “ee29503” mod bat twin pro 2x6ab003 40a wco “ee29503” ee* special specifications of the client. Co “made in spain” marking in the ups and its packaging (custom issue). W neutral brand equipment. (b0) no batter...

  • Page 14

    14 3.3. Operating principle. This manual describes the installation and operating of the un- interruptible power supply (ups) from slc twin pro series as equipments that can run as a complete separate and inde- pendent units. Upss from slc twin pro series assures an optimal protection for any critic...

  • Page 15

    15 salicru to be inserted into the slot that the ups has in its rear side. The connection of the ups with the snmp is internal meanwhile the connection between the snmp and the it network is done through a rj45 connector 10 base. 3.4.4. Relays interface card. See section 4.3.6.4.. 3.4.5. Modbus prot...

  • Page 16: 4.  Installation.

    16 4. Installation. • check the safety instructions, from section 1.2.3. • check that the data in the nameplate are the required by the installation. • a wrong connection or manoeuvring, can make faults in the ups and/or loads connected to itself. Read carefully the in- structions of this manual and...

  • Page 17

    17 salicru – the own module. – 1 trunk with anderson connectors at its ends in order to do the connection between the battery module and the equipment. – 1 connection cable for the earth protection, to joint between the equipment and module. • once the reception is finished, it is advisable to pack ...

  • Page 18

    18 4.3.2. Connection to output. • as this is a device with class i protection against electric shocks, it is essential to install a protective earth conductor (connect earth( )). Connect the con- ductor to the terminal, before connecting the power supply to the input ups. • all the equipments have 2...

  • Page 19

    19 salicru 4.3.4. Connection of main input earth terminal ( ) and the earth bonding terminal ( ) . • as this is a device with class i protection against electric shocks, it is essential to install a protective earth conductor (connect earth ( )). Connect the conductor to the terminal or bar, before ...

  • Page 20

    20 sw2 "on" sw3 "off" sw1 (*) relays interface card internal relays 14 7 1 (gnd) 13 12 11 10 9 6 5 4 3 2 8 fig. 8. Relays interface pin-out. Installation. • remove the protection cover from the relays interface slot of the equipment. • take the relays interface card and insert it into the reserved s...

  • Page 21: 5.  Operating.

    21 salicru 5. Operating. 5.1. Ups commissioning and shutdown. 5.1.1. Preliminary controls. • make sure that all connections have been done properly, and respecting the labelling of the equipment and the instructions of chapter 4. • check that the power supply is correct. • check that the ups is off ...

  • Page 22

    22 6. Control panel with lcd. 6.1. Control panel. Fig. 10. Control panel view. Key function description select key ups on bypass mode, the output voltage, frequency and bypasss enabling/disabling can be selected by pressing the key select and validated with enter. Enter key off ups shutdown press fo...

  • Page 23

    23 salicru bypass operating information inverter operating information output informat. Load informat. Battery information informat. Of the mode/ fault/ warning codes informat. To select the output voltage and frequency and the bypass enabling and disabling input informat. Fig. 11. Display lcd panel...

  • Page 24

    24 6.2.3. Line mode. The lcd panel on line mode is shown in figure 14. The infor- mation about mains, battery, ups output and load will be dis- played. The ups operating code is «2». In the same figure that the «inverter» stage is displayed (frame with inverter inscription inside) and active, it mea...

  • Page 25

    25 salicru 6.3. Settings through the lcd panel of the synoptic. Output voltage and frequency, bypass status, eco mode and con- verter mode can be set through the lcd panel of the ups directly. Output voltage can be set to 208 v, 220 v, 230 v and 240 v. Output frequency can be set to 50 hz or 60 hz. ...

  • Page 26: Service.

    26 7. Maintenance, warranty and service. 7.1. Battery maintenance. • pay attention to the safety instructions regarding battery and the stated in section 1.2.3.3. • the upss from slc twin pro series only requires a minimum maintenance. The used battery in the standard models is lead acid, sealed, vr...

  • Page 27

    27 salicru 7.2.1. Troubleshooting guide. Warning indications. If the ups doesn’t work properly, before calling s.S.T. Try to resolve the problem using the information in the following table: problem possible cause solution no warning indications, although the ups is connected to mains. No input volt...

  • Page 28

    28 7.3. Warranty conditions. The limited warranty only applies to those products that you ac- quire for commercial or industrial use in the normal development of your business. 7.3.1. Covered product. Ups slc twin pro series. 7.3.2. Warranty terms. This product is guaranteed against any parts and/or...

  • Page 29: 8.  Annexes.

    29 salicru 8. Annexes. 8.1. General technical specifications. Available powers (kva / kw) 0.7 / 0.56 1 / 0.8 1.5/ 1.2 2 / 1.6 3 / 2.4 technology on-line double conversion, pfc, double dc bus rectifier tipology of the input single phase quantity of wires 3 wires - phase r(l) + neutral (n) and earth n...

  • Page 30

    30 available powers (kva / kw) 0.7 / 0.56 1 / 0.8 1.5/ 1.2 2 / 1.6 3 / 2.4 end battery voltage: - from 0-30 % load, block / set 10.7 v dc / 32.1 v dc 10.7 v dc / 85.6 v dc - from 30-70 % load, block / set 10,2 v dc / 30.6 v dc 10.2 v dc / 81.6 v dc - from > 70 % load, block / set 9.5 v dc / 28.5 v d...

  • Page 31

    31 salicru power but in alternating current can defer depending on the power factor. • lcd.- lcd acronym of liquid crystal display, device in- vented by jack janning, who was employee of ncr. It is an electric system of data presentation based on 2 transparent conductor layers and in the middle a sp...

  • Page 32

    Uninterruptible power supply (ups) + lighting flow dimmer stabilizers (iluest) + switch mode power supply + static inverters + photovoltaic inverters + voltage stabilizers and power line conditioners avda. De la serra, 100 08460 palautordera barcelona tel. +34 93 848 24 00 902 48 24 00 (only spain) ...