Samlexpower SeC-1215UL Owner's Manual - Section 5 |
14 | SAMLEX AMERICA INC.
SAMLEX AMERICA INC. | 15
seCtIOn 5 |
Installation & Charger Operation
ing,thebatterywillautomaticallypower
theDCload.AssoonastheACpowerto
thechargerisrestored,theDCloadwill
onceagainbefedbythechargerandat
thesametimethebatterywillbe
recharged.
cAUtion! Please ensure that the sum of
the current drawn by the Dc load and the
current desired for charging the battery is
less than the maximum current capacity
of the charger.
TouseasaDCUPS,firstswitchoffthe
DCloadandconnectittothebattery.
Nowconnectthebatteryasexplained
aboveunder"ChargingaBatteryoutside
theVehicle"onpage14.Switchonthe
chargerandthenswitchontheDCload.
seCtIOn 6 |
troubleshooting
SYMPtoMS: cHARgeR PoweReD
AnD connecteD to tHe BAtteRY
the Red leD is oFF
TheDCsidefusemayhaveblowndueto
wrongpolarityofbatteryconnection.
EnsurePositiveofthebatteryisconnected
tothePositiveofthechargerandthe
Negativeofthebatteryisconnectedto
theNegativeofthecharger.Checkthe
fusesinsidethechargerandreplace,if
blown.
Thebatterymaybeshorted.Inthiscondi-
tion,theunitisshutdownbytheshort
circuitprotectioncircuit.Removethe
batteryconnection.IftheredLEDnow
comeson,thebatteryisshorted.Ifthered
LEDstilldoesnotcomeon,checkifthere
isACpowerinthereceptacle.Ifthereis
power,checktheACsidefuseinsidethe
unit.Ifthefuseisnotblown,callTechnical
Support.
the Red leD is on but the Ammeter
Shows no Reading
Thebatteryisfullycharged.Ifthebattery
isnotfullycharged,theconnectiontothe
batterymaybelooseoropen.Checktightness
andcontinuityofthebatteryconnection.
the Battery is getting over
charged or Boils
ThechargerisalsofeedingotherDC
load(s)inparallelwiththebattery.The
DIPSwitchisnotselectedfor"Battery
withLoad".ChangeDIPSwitchsettingto
"BatterywithLoad"(seeunder"Powering
otherDCloads"onpage14.
SYMPtoMS: cHARgeR PoweReD
& DiSconnecteD FRoM BAtteRY
the Red leD is oFF
CheckthereisACpowerinthereceptacle.
Ifthereispower,checktheACsidefuse
insidetheunit.Ifthefuseisnotblown,
checktheDCsidefuse.IftheDCsidefuse
isnotblown,theoutputmaybeshorted.
Inthiscondition,thechargerisshutdown
bytheshortcircuitprotectioncircuit.
Checkthattheoutputterminalsarenot
shorted.Iftheterminalsarenotshorted,
callTechnicalSupport.