Internal Fuse ratings & specifications
BoththeACsideandDCsideshavefusesthatarelocatedinsidethecharger.Disconnect
theACpowerwhencheckingorchangingthefuses.Openthechargerasfollows:
1. Removethe4screwsontheammetersideofthetopcover
2. gently slide the top cover out by about 2 to 3 inches.
(cAUtion! the top cover will be restrained from fully sliding out by the wires
connecting the ammeter , leD and fan)
3. Thefuseswillnowbeaccessible
FuseRatingsTable
FUSe RAtingS
Sec-1215Ul
Sec-1230Ul
Sec-2415Ul
120VACINPUT
4A/125V
8A/125V
8A/125V
DCOUTPUT
20A/32V
2x20A/32V
2x10A/32V
230VACINPUT
2A/250V
4A/250V
4A/250V
DCOUTPUT
20A/32V
2x20A/32V
2x10A/32V
SpecificationsTable
SPeciFicAtionS
Sec-1215Ul
Sec-1230Ul
Sec-2415Ul
NominalInputVoltage(pre-set)
120VAC,60Hz,
3.3A
120VAC,60Hz,
6.5A
120VAC,60Hz,
6.5A
InternalJumperChange
230VAC,50Hz
230VAC,50Hz
230VAC,50Hz
InputFrequency
50-60Hz
50-60Hz
50-60Hz
OutputVoltage,Boost
1,2
14VDC,or14.4
VDCordisabled
14VDC,or14.4
VDCordisabled
28VDC,or28.8
VDCordisabled
OutputVoltage,Float
1
13.5VDC
13.5VDC
27.0VDC
OutputAmps
15A
30A
15A
OperatingTemperatureRange
0-40°C
0-40°C
0-40°C
Weight
2.2kg./4.8lbs.
2.9kg./6.4lbs.
2.9kg./6.4lbs.
HousingDimensions
(LxWxH)Inches/Millimetres
8.5x8.4x3.3/
218x214x83
10.8x8.4x3.3/
280x214x83
10.8x8.4x3.3/
280x214x83
Protections
Short Circuit
Overload
Short Circuit
Overload/Over
Temperature
Short Circuit
Overload/Over
Temperature
OutputBanks
3
3
3
SafetyCompliance
i)ConformstoANSI/ULSTD1564
ii)CertifiedtoCAN/CSASTDC22.2No.107.2
EMICompliance
FCCPart15(B),ClassB
1.Voltagesbasedonbatterytemperatureof80°F
2.BasedonselectionbyDIPSWITCH.Seepages8&9
Specificationsaresubjecttochangewithoutnotice.