Summary of CLR2160

  • Page 1

    ® the built-in undercounter leader since 1962 clear ice models clear ice combo models ice combo models u-line.Com co1175 co2175 clr2160 clrco2175 install guide co29.

  • Page 2

    Safety precautions safety alert definitions.........................................................................................................................................1 general precautions .....................................................................................................

  • Page 3

    U-line safety precautions 1 important important • please read all instructions before installing, operating, or servicing the appliance. • proper installation procedures must be followed when completing an installation or relocation of a unit. Consult the installation guide before any installation b...

  • Page 4

    U-line inspect & plan 2 3 inspect & plan product registration you have received a carton containing your u-line clear ice, ice or ice combo unit with a package inside containing a use and care guide, a product registration card, and a water line kit. Please complete and mail the product registration...

  • Page 5

    Prepare site 3 4 prepare site your u-line product has been designed for either free-standing or built-in installation. When built-in, your unit does not require additional air space for top, sides, or rear. However, the front grille must not be obstructed and clearance is required for an electrical ...

  • Page 6

    Product dimensions 4 5 product dimensions clr2160 series co1175 series co29 series 23” * 28-1/2" 20-13/16" *add 15/16” to depth for water line clearance 4-3/4” 34-1//8" 24" black and white stainless steel 34-1/8" 24” 3-13/16” 3-13/16” 23” 23” *add 3/4” to depth for water line clearance *add 3/4” to ...

  • Page 7

    Door swing dimensions 5 6 door swing dimensions all units have a zero clearance for the door to open 90°. U-line recommends a minimum door clearance of 2” to accommodate the handle if the unit is installed next to a wall. Other site requirements side-by-side installation for a complete refreshment c...

  • Page 8

    U-line standrd door alignment and reversal 6 7 standard doors door alignment and adjustment align and adjust the door if it is not level, or is not sealing properly. If the door is not sealed the unit may not cool properly, or excessive frost may form in the interior. Important important properly al...

  • Page 9

    U-line standrd door alignment and reversal 7 install bottom hinge: 1. If you have a plate hinge, reorient the pivot screw so it protrudes the opposite direction form the hinge. Remove the pivot screw from the hinge. Turn the plate over and reinstall the screw. 2. Align hinge outer edge with cabinet....

  • Page 10

    U-line self-closing door alignment and reversal 8 1/8" (3.175 mm) 1 2 3 4 8 self-closing doors door alignment and adjustment align and adjust the door if it is not level, or is not sealing properly. If the door is not sealed the unit may not cool properly, or excessive frost may form in the interior...

  • Page 11

    U-line self-closing door alignment and reversal 9 3 4 uli 5 notch 1 2 to reverse the door: remove door: 1. Hold door to keep it from falling. 2. Remove hinge screw pin (1) from top hinge using a phillips screwdriver. 3. Remove door by tilting forward and lifting door off bottom hinge closer inserts....

  • Page 12

    U-line door panel installationl 10 9 door panel installation custom 1/4'' thick door panel insert door panel preparation a custom door panel may be inserted into the doorframe. Custom door panels can be flat or raised, as long as the maximum panel thickness, where inserted into the door reveal (chan...

  • Page 13

    U-line grill overlay installation 11 grille overlay (excludes co1175) your models grille is designed to accept a wood grille over- lay. An overlay may be used to compliment a door overlay and provides a seamless look for your surrounding decor. Follow the instructions below to prepare and install yo...

  • Page 14

    U-line grill overlay installation 12 1/4 8-1/2 3-3/32 19-5/8 1/2 1/2 typ 3x 5/16 typ 2x (7/16 ) 5/16 10-5/16 11/64 2-1/8 1/2 22-7/8 23-7/8 full r grille ov erla y dimensions 24 inch models grille drawing 24 inch.

  • Page 15

    U-line grill overlay installation 13 1/4 4-5/32 3-3/32 10-5/8 1/2 1/2 typ 3x 5/16 typ 2x (15/32 ) .275 5-29/32 11/64 2-1/8 1/2 13-7/8 14-7/8 full r grille ov erla y dimensions 15 inch models grille drawing 15inch.

  • Page 16

    U-line electrical / plumbing specfications 14 11 prepare power supply electrical specifications warning shock hazard — electrical grounding required. • never remove the round grounding prong from the plug and never use a two-prong grounding adapter. • never use an extension cord to connect power to ...

  • Page 17

    U-line plumbing specfications 15 warning prior to attempting installation, determine if this product contains a gravity style drain or factory installed drain pump. Products without a drain pump may only use a gravity style drain. Failure to connect water supply or drain line connections properly ma...

  • Page 18

    U-line plumbing specfications 16 drain connection: caution if your u-line unit did not come with a factory installed drain pump you must use a gravity style drain connection. For assistance in determining if your unit has a pump please contact u-line. The floor drain must be large enough to accommod...

  • Page 19

    U-line plumbing specfications 17 important important the maximum lift for the p60 drain pump is 10 feet. This must be done as close to the rear of the unit as possible. Important important before installing your u-line clr2160 or clrco2175 with factory-installed u-line p60 pump, it is extremely impo...

  • Page 20

    Level & install unit 18 12 level the unit leveling information it is recommended that the unit is level. 1. Use a level to check the levelness of the unit from front to back and from side to side. Level should be placed along top edge and side edge as shown 2. If the unit is not level, adjust the fe...

  • Page 21

    Level & install unit 19 installation troubleshooting problem q: water is leaking under the unit. Solution a: a water leak under the unit is most likely caused by a bad connection in the water supply line. Make sure the water line’s brass fitting is screwed tight to its valve and threaded correctly. ...

  • Page 22: Installation Guide

    ® about u-line building on 45 years, u-line has captivated those with an appreciation for the finer things with exceptional design, inspired innovations and attention to even the smallest details. U-line is synonymous with premium built-in undercounter ice making, refrigeration and wine storage appl...