3. Carefully bend the water supply line into position and
connect the line to the solenoid valve (see Figure 40).
Avoid kinking the water supply line.
IMPORTANT
Normal operation creates some vibration. A water supply
line contacting cabinet wall may cause excessive noise
during operation or damage to the line.
4. For recessed installations, allow extra water supply line
length to provide slack for easy removal from the
recessed area (see Figure 40). This will also safeguard
against kinking the line.
5. Go on to 7 Prepare Power Supply.
Electrical Specifications
CAUTION
Electrical installation must observe all state and local
codes. This unit requires connection to a grounded (three-
prong), polarized receptacle that has been placed by a
qualified electrician.
The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A power supply (normal household current).
An individual, properly grounded branch circuit or circuit
breaker is recommended. GFCI (ground fault circuit
interrupter) is usually not required for fixed location
appliances and is not recommended for your unit because
a GFCI could be prone to nuisance tripping. However, be
sure to consult your local codes.
See Figure 41 for recommended receptacle location.
Plugging the unit into a receptacle located behind an
adjacent cabinet will allow the CLRCO2175 to be more
easily serviced with self-diagnostics without disturbing
your installation.
WARNING
SHOCK HAZARD — Electrical Grounding Required.
• Never remove the round grounding prong from
the plug and never use a two-prong grounding
adapter.
• Never use an extension cord to connect power to
the unit.
Go on to 8 Level the Unit.
Figure 40
7 Prepare Power Supply
Acceptable
Location
Preferred
Location
for CLRCO2175
Receptacle
1-1/2"
7"
24"
Figure 41