Charger Indicator Lights
6 – BULK/ABSORPTION INDICATOR LIGHT
(See ‘Battery Charger Theory of Operation’ for battery charging performance details.)
Light Action
Description
Blinking Yellow
The unit is in Charger Mode (shore power is present) and the
charger is in either the BULK STAGE or ABSORPTION STAGE of
the battery charging cycle.
7 – FLOAT INDICATOR LIGHT
(See ‘Battery Charger Theory of Operation’ for charger performance details.)
Light Action
Description
Solid Green
The unit is in Charger Mode (shore power is present) and the charger
is in the FLOAT STAGE of the battery charging cycle.
Remote Control Terminals
8 – REMOTE PANEL OR IFM1 JACK
Eight-wire modular jack for use with optional SR10 Remote or IFM1. (The six-conductor
IFM1 cable will work in this jack.)
9 – INVERTER CONTROL TERMINAL
A 1/4" spade connector for use with an external 12v source for inverter remote control.
Configuration switches 4 and 5 must be UP to activate this feature. The inverter will turn
ON when a continuous 12 volt signal is applied, and turn OFF when the 12 volt signal goes
away. The SR10 Remote Control Panel is required to initially turn the inverter ON after
connection to battery voltage.
Configuration Switches
10 – LOAD DEMAND ON/OFF (SWITCH 1)
Turn Load Demand Function ON/OFF. See definition of Load Demand in Section 1.3.
With Load Demand ON the inverter operates only when a load greater than 5 Watts is
applied. Some electronic or variable speed loads may not turn ON while the inverter is in
Load Demand.
11 – BATTERY TYPE WET/GEL (SWITCH 2)
Select wet or gel battery-charging voltages.
12 – CHARGING RATE HIGH/LOW (SWITCH 3)
Select 55 amp charge rate in High or 15 amp charge rate in Low.
13 – REMOTE CONTROL SELECTOR IFM1/REMOTE (SWITCH 4)
Set to Remote for use with SR10 Remote. Set to IFM1 for use with IFM1 or no remote.
14 – INVERTER CONTROL TERMINAL ENABLE/DISABLE (SWITCH 5)
Activates function of Inverter Control Terminal when Switch 4 is in Remote. When enabled, a
continuous 12v signal is REQUIRED to turn the inverter function ON. SR10 Remote is REQUIRED
to initially turn the inverter ON after connection to battery voltage.