2.2.10 Wake-up / Sleep
Wake-up
The
GL1000
/
GL1010
starts after power on. A sleeping logger wakes up
>
after reception of a CAN message
>
after reception of a LIN message
>
positive edge on the wake line (clamp 15)
>
wake-up timer via real-time clock
The logger has to be equipped with CAN transceivers with wake-up capability to
support the wake-up functionality on CAN (see section 2.4 Piggybacks).
The wake-up line resists the full board voltage. If the
GL1000
is supplied from clamp
30, the wake-up line can be connected with clamp 15. Thereby the
GL1000
will be
woken up immediately at switching on the ignition even if no activity is on the wake-up
compatible busses or the busses are not connected.
Sleep
The logger can be configured to go to sleep mode if no CAN and LIN messages are
received for a defined time. This time can be configured (max. 18000 s = 5 h).
2.2.11 CCP/XCP
Overview
The
GL1000
/
GL1010
supports the recording of CCP/XCP data in DAQ and polling
mode. The A2L file is inserted directly in the
Vector Logger Configurator
and the
signals to be measured are selected.
For ECUs which are protected via Seed & Key procedure
CANape
is also required to
program the Seed & Key algorithm and create an SKB file containing this algorithm.
This SKB file is added to the logger configuration.
CCP/XCP is available as option. The license must be installed in the logger. The
license also includes the Seed & Key support.
FAQ
Measurement mode
DAQ (
data aquisition) mode, polling mode
Supported CCP version
CCP 2.0 und CCP 2.1
Supported XCP version
XCP 1.0 and higher
Configuration
Vector Logger Configurator
V2.5 or higher
CANape
for Seed & Key only
Alternative:
CANape
V8.0 or higher for DAQ mode, Seed & Key
CANape
V13.0 or higher for polling mode
A2L file
Direct import in Vector Logger Configurator
Import in
CANape
still available
Number of ECUs
Multiple ECUs possible