Vega VEGAPULS 67 Product Information - page 4
4
Type overview
Radar - Level measurement in bulk solids
29427-EN-160312
2 Type overview
VEGAPULS67
VEGAPULSSR68
VEGAPULS68
Applications
Bulk solids
Bulk solids under extremely difficult pro-
cess conditions
Bulk solids under extremely difficult pro-
cess conditions
Max. measuring range
15 m (49.21 ft)
30 m (98.43 ft)
75 m (246.1 ft)
Antenna/Material
Completely encapsulated plastic horn an-
tenna/PP
Horn or parabolic antenna/316L
Horn or parabolic antenna/316L
Processfitting/Material
Mounting strap/316L or flange/PP
Thread G1½/316L according to DIN 3852-
A or flange/316L
Thread G1½/316L according to DIN 3852-
A or flange/316L
Process temperature
-40 … +80 °C (-40 … +176 °F)
-40 … +250 °C (-40 … +482 °F)
-196 … +450 °C (-321 … +842 °F)
Process pressure
-1 … +2 bar/-100 … +200 kPa
(-14.5 … +29.0 psig)
-1 … +100 bar/-100 … +10000 kPa
(-14.5 … +1450 psi)
-1 … +160 bar/-100 … +16000 kPa
(-14.5 … +2320 psi)
Deviation
±2 mm
±2 mm
±2 mm
Frequency range
K-band
K-band
K-band
Signal output
•
4 … 20 mA/HART - two-wire
•
4 … 20 mA/HART - four-wire
•
Profibus PA
•
Foundation Fieldbus
•
Modbus, Levelmaster protocol
•
4 … 20 mA/HART - two-wire
•
4 … 20 mA/HART - four-wire
•
Profibus PA
•
Foundation Fieldbus
•
Modbus, Levelmaster protocol
•
4 … 20 mA/HART - two-wire
•
4 … 20 mA/HART - four-wire
•
Profibus PA
•
Foundation Fieldbus
•
Modbus, Levelmaster protocol
Indication/Adjustment
•
PLICSCOM
•
PACTware
•
VEGADIS 81
•
VEGADIS 82
•
PLICSCOM
•
PACTware
•
VEGADIS 81
•
VEGADIS 82
•
PLICSCOM
•
PACTware
•
VEGADIS 81
•
VEGADIS 82
Approvals
•
ATEX
•
IEC
•
FM
•
CSA
•
ATEX
•
IEC
•
Shipbuilding
•
FM
•
CSA
•
ATEX
•
IEC
•
Shipbuilding
•
FM
•
CSA