Vent-Axia Sentinel User, Installation & Maintenance Manual

Manual is about: Kinetic MVHR & Cooker Hood

Summary of Sentinel

  • Page 1

    Copyright © 2009 vent-axia limited. All rights reserved. Sentinel kinetic mvhr & cooker hood user, installation, commissioning & servicing instructions stock ref. N° 441483 kinetic cwl 441484 kinetic csl 441485 kinetic cwr 441486 kinetic csr please retain these instructions with the product. Read in...

  • Page 2

    Safety information 2 sentinel kinetic mvhr with cooker hood installation & commissioning important please read these instructions carefully before commencing installation. 1. Read the safety instructions on page 2 of the sentinel kinetic mvhr installation & commissioning and operation & monitoring d...

  • Page 3

    About this document sentinel kinetic mvhr with cooker hood installation & commissioning 3 contents product description 4 sentinel kinetic mvhr with cooker hood ..................................... 4 user information ............................................................................. 5 tec...

  • Page 4

    Product description 4 sentinel kinetic mvhr with cooker hood installation & commissioning product description sentinel kinetic mvhr with cooker hood the vent-axia sentinel kinetic mechanical ventilation heat recovery (mvhr) unitis a heat recovery unit with a cooker hood designed for the energy effic...

  • Page 5

    Product description sentinel kinetic mvhr with cooker hood installation & commissioning 5 models 441483, 441484, 441485, 441486 - sentinel kinetic with cooker hood and with summer bypass. An internal damper is activated when the outside temperature is equal to, or greater than, the pre-set ‘comfort ...

  • Page 6

    Technical specification 6 sentinel kinetic mvhr with cooker hood installation & commissioning technical specification sentinel kinetic with cooker hood technical specification performance airflow refer to sentinel kinetic installation & commissioning document page 5 flow for cooker hood adjustable u...

  • Page 7

    Technical specification sentinel kinetic mvhr with cooker hood installation & commissioning 7 figure 2: sentinel kinetic with cooker hood dimensions.

  • Page 8

    8 sentinel kinetic mvhr with cooker hood installation & commissioning figure 3: sentinel kinetic with right hand cooker hood dimensions.

  • Page 9

    Sentinel kinetic mvhr with cooker hood installation & commissioning 9 figure 4: sentinel kinetic with left hand cooker hood dimensions.

  • Page 10

    Installation 10 sentinel kinetic mvhr with cooker hood installation & commissioning installation overview the following instructions are intended to help prevent potential hazards and should be carried out only by a qualified electrician and installer. Before installing the unit inspect the unit whe...

  • Page 11

    Installation sentinel kinetic mvhr with cooker hood installation & commissioning 11 condensate horizontal discharge installation to install the condensate horizontal outlet refer to sentinel kinetic installation & commissioning document page 11. Spigot installation see sentinel kinetic installation ...

  • Page 12

    Installation 12 sentinel kinetic mvhr with cooker hood installation & commissioning 5. Replace the “l” shaped duct front cover and tighten the three screws wall mounting 6. A wall mounting template can be obtained from vent axia technical support or refer to pages 8 & 9 for dimensions. 7. If you are...

  • Page 13

    Installation sentinel kinetic mvhr with cooker hood installation & commissioning 13 fitting cooker hood to left hand unit 1. Remove the cooker hood light cover using cross type screwdriver. 2. After removing the light cover, turn the cooker hood to its opposite face. Unscrew the cable clip from insi...

  • Page 14

    Installation 14 sentinel kinetic mvhr with cooker hood installation & commissioning attach ducting see the sentinel kinetic installation & commissioning document. Electrical installation see the sentinel kinetic installation & commissioning document. Commissioning see the sentinel kinetic installati...

  • Page 15

    Installation sentinel kinetic mvhr with cooker hood installation & commissioning 15 maintenance caring for the unit heat recovery units, by their very nature, require regular maintenance. The sentinel kinetic has been designed to facilitate access to enable maintenance to be carried out easily. Warn...

  • Page 16

    Installation 16 sentinel kinetic mvhr with cooker hood installation & commissioning spares the following spares may be ordered from vent-axia: table 1: spares part no description 441768 main power board 441767 control panel 441774 filters, 2-pack (bypass version 438222) 441764 heat recovery cell (by...

  • Page 17

    Appendix a: options and accessories sentinel kinetic mvhr with cooker hood installation & commissioning 17 appendix a: options and accessories humidistats an optional internal humidistat is available as an accessory. (part number 441838). This adjusts the fan speed proportionally depending on the te...

  • Page 18

    Head office: fleming way, crawley, west sussex, rh10 9yx. Uk national call centre, newton road, crawley, west sussex, rh10 9ja sales enquiries: tel: 0844 8560590 fax: 01293 565169 technical support tel: 0844 8560594 fax: 01293 532814 for details of the warranty and returns procedure please refer to ...