Vent-Axia Sentinel User, Installation & Maintenance Manual - page 13
Installation
Sentinel Kinetic MVHR with Cooker Hood Installation & Commissioning
13
Fitting Cooker Hood to Left Hand Unit
1. Remove the cooker hood light cover using
cross type screwdriver.
2. After removing the light cover, turn the cooker
hood to its opposite face. Unscrew the cable
clip from inside, then insert the cable with its
connector (fig. 8) through aperture gently by
pulling it to your right as far as it will extend.
3. Feed the cable with its plug through the
aperture on the right hand side (fig. 9).
4. Turn the cooker hood to its opposite face, pull
the cable through as far as it extends. Use the
existing cable clip and its screw to secure the
cables to the hood as shown (fig. 10).
5. Now the cooker hood is ready to fit to the
metal duct unit.
6. Go to instructions for Fitting Cooker Hood to
Right Hand Unit, items 1-15 on pages 9 and
10.
Figure 8: Passing cable through
Figure 9: Insert cable opposite direction
Figure 6: Using cable clip to secure the cable