Vent-Axia Sentinel User, Installation & Maintenance Manual - page 15
Installation
Sentinel Kinetic MVHR with Cooker Hood Installation & Commissioning
15
Maintenance
Caring for the Unit
Heat recovery units, by their very nature, require regular maintenance. The Sentinel Kinetic has been designed
to facilitate access to enable maintenance to be carried out easily.
WARNING
THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY
DURING MAINTENANCE.
Cooker Hood Cleaning Interval
For MVHR unit maintenance, refer to Sentinel Kinetic Installation & Commissioning and Operation & Monitoring
documents.
Item
Action
Cooker Hood Filters
Clean Filters every six months or more frequently if the style of cooking requires it. For
instruction how to remove filters see below.
Cooker Hood Adaptor
Switch off the unit at the wall isolator before cleaning any component. Remove cover and
wipe the interior clean every six months or more frequently if the style of cooking requires it.
After cleaning ensure that the cover is replaced correctly and screws tightened. Do not use
water or spray cleaning agents for cleaning the space, however a damp or dry cloth may be
used.
Removing
Filters.
a)
Rear Filter – To remove the rear filter grip and pull inwards the grey levers at either side and slide the
filter forwards and downwards.
b)
Front Filter – To remove the front filter grip and pull inwards the grey levers at either side and drop
the filters downwards.
c)
The filters can be washed in a dishwasher or soapy water. Thoroughly dry the filters and reassemble
in reverse order.